3. Operating the UPS

3. Operating the UPS

3-1 Precautions and notes on operation

During the operation, follow the do's and don'ts below.
In a case where the Battery Replacement Lamp comes on or the backup
time becomes shorter than the required backup time, replace with a new
battery pack while the UPS is running, or stop the UPS and discard the
old battery pack.
● The continuous operation of the UPS may cause a fire.
● For further information on how to inspect the battery, see "6. Maintenance and inspection" on
page 33.
Ambient
temperature
20°C
30°C
In case where you notice abnormal sound or smell, smoke, or liquid from
the inside of the UPS, press the Stop switch of the UPS immediately and
remove the AC Input Plug from a wall outlet (commercial power).
● A continuous operation under the abnormal conditions may cause a leakage of current or
fire.
● If you notice the abnormal conditions, never operate the UPS and contact the distributor from
which you purchased your UPS or us for inspection and repair.
● Your UPS must permit to remove AC Input Plug from a wall outlet (commercial power) in-
stantly at the onset of a failure.
Before maintaining devices connected to the UPS, turn off the UPS and
remove the AC Input Plug from a wall outlet (commercial power).
● Even if you remove the AC Input Plug during the operation of the UPS, the backup function of
the UPS keeps feeding power through the power supply output receptacle of the UPS.
● In a case where the scheduled operation is ON and the AC Input Plug of the UPS is put in a
wall outlet (commercial power), the UPS starts feeding power at the starting time of the sched-
uled operation.
When the input plug accidentally become removed while the UPS is
running, never touch the metal part of the input plug.
● Doing so may cause an electric shock.
● A leak current of the UPS is less than the value of safety standard (leak current: 1mA) how-
ever, the leak current may increase due to the devices connected. Therefore, never touch the
metal part of the input plug.
Do not place things on the UPS or do not drop metal things into the UPS.
● Doing so may cause distortion and/or damage to the top case of the UPS or an internal circuit
failure, which may leads to a fire.
Do not place the UPS in an enclosed space or put a cover over the UPS.
● Doing so may lead to an abnormal overheat or fire.
Do not wet or spill water on the UPS
● Doing so may cause an electric shock or fire.
Estimated life
expectancy
* The left table shows the estimated life expectancy of a
4 to 5 years
battery pack on the ground that the battery is used in the
usual way. They are not the warranty period.
2 to 2.5 years
Cautions
(use)
24