ELEVATION (FT)
ABOVE SEA LEVEL
0-1000
1000-2000
2000-3000
3000-4000
4000-5000
5000-6000
6000-7000
7000-8000
8000-9000
9000-10000
NOTE: No more than two offsets (four elbows) allowed. Two 45
RECOMMENDED
HEIGHTS FOR
WOODSTOVE FLUE
Simple rules on draft. See Table 1.
1) At sea level minimum height is 12'
straight.
2) Add the following vertical height to compen-
sate for:
45 deg. elbow
= 1 ft.
90 deg. elbow
= 2 ft.
"T"
= 3 ft.
Each foot of horizontal run = 2 ft.
3) Add 4% overall for each 1000' above sea
level.
Example: a)
1-1/2 ft. of horizontal run
one "T"
Total Addition (at sea level)
Example: b)
One 90 deg. elbow
2 ft. of horizontal run
one "T"
Total Addition (at sea level)
Recommended Flue Height
Elevation
Example a)
0'
18'
1000'
18.72'
2000'
19.44'
5000'
21.60'
8000'
23.76'
Regency F1100/F3100 Freestanding Woodstove
MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET
(Measured from the top of the unit)
0
12.0
12.5
13.0
13.5
14.0
14.5
15.0
15.5
16.0
16.5
Once you have properly marked the position
of your unit and the fl oor protection as outlined
in the Residential Installation items #1 through
#8, a supply of fresh air has to be supplied to
your unit. Cut a minimum 4 inch diameter hole
through your fl oor protector and the fl oor directly
under your pedestal base to the outside. Use
4" duct pipe with a mesh grill to pipe fresh air
into the pedestal area. Block off the hole in the
back of the pedestal with the square plate and
the two 1/2" screws provided.
Place your unit in position and secure it to the
fl oor using two lag bolts 3/8" x 3-1/2" through
the two holes inside the pedestal base. It is
important to maintain the structural integrity
of the Mobile Home fl oor, walls and roof when
installing your unit.
= 3 ft.
For Mobile Home units installed in the U.S. the
= 3 ft.
unit must be grounded using a #8 ground wire
= 6 ft.
with approved termination and star washer.
WARNING:
= 2 ft.
Minimum height requirements
= 4 ft.
must be met. Safe removal of
= 3 ft.
the chimney system must be
= 9 ft.
adhered to when transporting the
mobile home.
Example b)
21'
21.84'
22.68'
WARNING: Operate only with door fully
25.20'
closed - open feed door to feed fi re only.
27.72'
TABLE 1
# OF ELBOWS
2 x 15
o
4 x 15
o
2 x 30
13.0
14.0
15.0
13.5
14.5
15.5
14.0
15.0
16.0
14.5
15.5
17.0
15.0
16.0
17.5
15.5
17.0
18.0
16.0
17.5
18.5
16.5
18.0
19.0
17.0
18.5
20.0
17.5
19.0
20.5
o
elbows equal one 90

MOBILE HOME INSTALLATION

INSTALLATION
o
4 x 30
o
2 x 45
o
4 x 45
18.0
16.0
20.0
19.0
16.5
21.0
19.5
17.0
21.5
20.0
18.0
22.5
21.0
18.5
23.0
21.5
19.0
24.0
22.5
20.0
25.0
23.0
20.5
25.5
24.0
21.0
26.5
24.5
22.0
27.0
o
elbow.
o
15