Page 1
Owners & Freestanding Woodstove Installation Manual www.regency-fire.com MODEL: F3500 Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. 219-S-18-2 919-336 FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4...
Page 2
Note: Due to the high efficiency of the F3500 unit. Double wall pipe is recommended from the stove top to either wall or roof exit. A minimum of 36" vertical rise is required prior to using any elbows.
TABLE OF CONTENTS Fan Installation ............21 Safety Label for F3500 ..........4 Operating Instructions ..........22 Unit Dimensions ............5 Draft Control ..............22 Residential Installation...........6 First Fire ..............22 Room Air - Important .............6 Fan Operation..............23 Modular Installation Options ..........6 Ash Disposal..............23 Stove Assembly Prior To Installation ......7 Safety Guidelines and Warnings .........23...
SAFETY LABEL FOR F3500 DO NOT REMOVE THIS LABEL LISTED ROOM HEATER, SOLID FUEL TYPE, ALSO FOR USE IN MOBILE HOME INSTALLATION MODEL: REGENCY FREESTANDING STOVE - F3500 OMNI-Test Laboratories, Inc. TESTED TO: UL-1482 -2011 / ULC-S627-00 219-S-18-2 Report # INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS.
WARNING: ONLY USE SPECIFIED COMPONENTS. The following items are required when assembling your Regency Stove. F3500 unit - the Rear Heat Deflector is supplied with the stove, but if you choose not to use it you must use the Airmate instead.
The F3500 unit requires the pedestal attached corner of the wall. The rear heat deflector is installed on top of to the base. The F3500 stove requires either pedestal cover the rear heat shield, as shown in Diagram 4. the Airmate or Rear Heat Deflector on top of plate.
521mm Minimum Alcove Clearance to Combustible Materials The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level. Note: Minimum alcove ceiling height - 83" (2108 mm) Vertical Termination} H = Maximum depth of alcove - 48"...
Minimum vertical of 36" before any offset. Horizontal Maximum of 36" with 1/4" rise per foot. Single Wall 18" [457mm] NOTE: Recommend using 2-45º instead of 90º to improve draft and performance. Min. 36" Vertical Max. 36" Rise Horizontal 10" [254mm] F3500 Regency Freestanding Woodstove...
fi replace damper. The existing damper may have to be removed to allow installation. Minimum vertical of 36" before any offset. Horizontal Maximum of 36" with 1/4" rise per foot. NOTE: Recommend using 2-45º instead of 90º to improve draft and performance. F3500 Regency Freestanding Woodstove...
Cover opening with and support chimney section on both sides with 24 gage minimum sheet metal supports. See that the supports are fastened securely to wall surfaces on all sides. Make sure fasteners used to secure chimney flue liner. F3500 Regency Freestanding Woodstove...
46-1/2 8" 46-1/2 8" Canada 48-1/2" 8" 48-1/2" 8" 48-1/2" 8" The rear clearance to combustibles is less than 6" (for corner installations the rear corners may be angled to take advantage of the closer clearances. F3500 Regency Freestanding Woodstove...
6. Fasten the raincap with spark screens (if required) to the top of your chimney. Horizontal Installation 7. For optimum efficiency when installing into a masonry chimney, size accordingly, i.e. the 6" (152.4mm) flue dia. is 28.28 sq.in. (718.31mm). F3500 Regency Freestanding Woodstove...
11. WARNING: DO NOT INSTALL IN A SLEEP- ING ROOM OF A MOBILE HOME. 12. Use silicone to create an effective vapour barrier at the location where the chimney or other component penetrates to the exterior of the structure. F3500 Regency Freestanding Woodstove...
Mark the position of your unit as outlined in the "General Information" and "Clearances to Combustibles" section of the manual. Pipe fresh air into the pedestal area by using a minimum 4" duct pipe with a mesh grill at the outside termination. Rear View F3500 Regency Freestanding Woodstove...
6DP-MH9096 Mobile Home Kit INSTALLATION ICC EXCEL 2100 Qty.Part # Description The Regency F3500B Freestanding pedestal 6CL48 48" Chimney length (also in units are approved for installation in a Mobile 12", 18", 24" lengths. Home if one of the following pipe systems is used.
WARNING: Operation of the unit with out proper installation of smoke deflector will void warranty. Incorrect Install: Return edge of smoke deflector seated under glass wash. Ensure defector is seated so bolts are situated at the top of the keyhole before tightening. Hand tighten bolts only. F3500 Regency Freestanding Woodstove...
4-1/2" x 9" 2" x 9" 3-1/2" x 4-1/2" 1-3/4" x 4-1/2" 4-1/2" x 7-5/8" AD brick NOTE: The "AD" brick covers the Ash Dump hole that is used when the Ash Drawer Kit is installed. Final Install F3500 Regency Freestanding Woodstove...
INSTALLATION REMOVABLE DOOR HANDLE The F3500 has a removable door handle that can be stored when not in use. Hook Handle The cool to touch door handle is designed to be inserted from the bot- tom up and slide off when not held in place. Once in position, the door can be opened.
Wiring errors can cause improper and dangerous operation. Neutral Manual/ Green Live Ground Auto 120V AC Switch Switch 60 Hz Fan Thermodisc (normally open) Black Black Black Ground Wiring Diagram 908-126a 04/08/14 F3500 Regency Freestanding Woodstove...
- slide to the left to open, and to decrease - slide to 3. With the catalytic by-pass damper still in the reaches temperature. the right closed. The F3500 unit has a secondary fully open position, add two or three seasoned draft system that continually allows combustion air logs to your fire.
Switching from "AUTO" to "MAN" or "HIGH" to 7. Your Regency stove can be very hot. You may be "LOW" may be done anytime. seriously burned if you touch the stove while it is...
Burning coal will cause a sulfur-based compound to coat the catalyst. Revert to burning wood and fire the combustor to elevated temperatures for one hour. F3500 Regency Freestanding Woodstove...
If the door gasket requires replacement 5/8" diameter form creosote. The creosote vapours condense in material must be used. Regency uses a gasket rope the relatively cool chimney flue of a slow burning 5/8" Medium Density (Part #846-530). A proper high fire.
– off has been achieved, to the 14.000 amount of smoke leaving the chimney when the smoke is not routed (by- pass open) through the combustor. F3500 Flamegaurd & Catalyst Mass = 4.649 pounds F3500 Regency Freestanding Woodstove TOTAL AREA FOR AIR FLOW = 37.396...
Page 27
NOTE: Replacement combustors can be retrieved from Applied Ceramics or Contact your local Regency Dealer for details. DO NOT OPERATE THE APPLIANCE IF COMBUSTOR BECOMES INACTIVE - DO NOT OPERATE WITHOUT COMBUSTOR.
5. Reverse steps to reinstall - ensure the pass rod is seated with the channel on the pass door. (Unit viewed as transparent to facilitate view) Channel Pass rod Loosen 3 rear bolts F3500 Damper Assembly Draft F3500 Regency Freestanding Woodstove...
Align tab on right side air channel with notch on right hand end of air tube. Firmly grip center of air tube with vise grips, use hammer to tap vise grips from left to right until the tube bottoms out into the air channel on right. F3500 Regency Freestanding Woodstove...
Use only high temperature anti seize lube. (ie. never seize) Check glass for cracks Replace if required. Clean blower motor Disconnect power supply. Remove and clean blower. *DO NOT LUBRICATE* Inspect and clean chimney Annual professional chimney cleaning recommended. F3500 Regency Freestanding Woodstove...
PARTS LIST F3500 STOVE BRICK LAYOUT 042-960 Brick Set Complete Fire bricks Size 4-1/2" x 9" 2" x 9" 3-1/2" x 4-1/2" 1-3/4" x 4-1/2" 4-1/2" x 7-5/8" F3500 Regency Freestanding Woodstove...
PARTS LIST DOOR ASSEMBLY Part # Description Part # Description 042-201 Door cast black (F3500) 846-530 5/8" Medium Door gasket kit 106-541/P Aligner assembly 042-021 Gasket bracket 156-514 Removable cast handle assembly 904-513 Hex bolt 1/4-20 x 3/4 LG. 940-416/P...
The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
Page 38
Any and all claims for catalytic combustor must be fi led by the consumer directly with APPLIED CERAMICS (full address below). FPI/Regency does not handle these claims. Please follow the instructions below for returning your catalytic converter under warranty. To learn more about the care and maintenance or the catalytic converter, please visit our website: www.fi...
Page 39
All warranty claims must be sent to: Regency Fireplace Products By Authorized Regency Dealer * Prices subject to change. * Regency reserves the right to reject any claim if it is determined the damage is a result of misuse, abuse or improper cleaning/ handling. F3500 Regency Freestanding Woodstove...