Recommended Heights For Woodstove Flue - Regency Alterra CS1200 Owners & Installation Manual

Freestanding wood stove
Table of Contents

Advertisement

INSTALLATION
ELEVATION (FT)
ABOVE SEA LEVEL
0-1000
1000-2000
2000-3000
3000-4000
4000-5000
5000-6000
6000-7000
7000-8000
8000-9000
9000-10000
NOTE: No more than two offsets (four elbows) allowed. Two 45
RECOMMENDED
HEIGHTS FOR
WOODSTOVE FLUE
Simple rules on draft. See Table 1.
1) At sea level minimum height is 12' straight.
2) Add the following vertical height to compensate
for:
45 deg. elbow
90 deg. elbow
"T"
Each foot of horizontal run = 2 ft.
3) Add 4% overall for each 1000' above sea level.
Example: a)
1-1/2 ft. of horizontal run
one "T"
Total Addition (at sea level)
Example: b)
One 90 deg. elbow
2 ft. of horizontal run
one "T"
Total Addition (at sea level)
Recommended Flue Height
Elevation
Example a)
0'
1000'
2000'
5000'
8000'
12
MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET
(Measured from the top of the unit)
# OF ELBOWS
0
2 x 15
12.0
13.0
12.5
13.5
13.0
14.0
13.5
14.5
14.0
15.0
14.5
15.5
15.0
16.0
15.5
16.5
16.0
17.0
16.5
17.5
= 1 ft.
= 2 ft.
= 3 ft.
= 3 ft.
= 3 ft.
= 6 ft.
= 2 ft.
= 4 ft.
= 3 ft.
= 9 ft.
Example b)
18'
21'
18.72'
21.84'
19.44'
22.68'
21.60'
25.20'
23.76'
27.72'
TABLE 1
o
o
o
4 x 15
2 x 30
4 x 30
14.0
15.0
14.5
15.5
15.0
16.0
15.5
17.0
16.0
17.5
17.0
18.0
17.5
18.5
18.0
19.0
18.5
20.0
19.0
20.5
o
elbows equal one 90
o
o
o
2 x 45
4 x 45
18.0
16.0
20.0
19.0
16.5
21.0
19.5
17.0
21.5
20.0
18.0
22.5
21.0
18.5
23.0
21.5
19.0
24.0
22.5
20.0
25.0
23.0
20.5
25.5
24.0
21.0
26.5
24.5
22.0
27.0
o
elbow.