Page 1
Classic™ Freestanding Woodstove Owners & Installation Manual F2450M French Manual Download: https://bit.ly/3rAsDW7 www.regency-fire.com Manuel en Français : https://bit.ly/3rAsDW7 MODEL: F2450M Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference.
Page 2
ASTM E3053. Model Regency F2450M – 2.3g/hr. "This manual describes the installation and operation of the Regency F2450M wood heater. This heater meets the 2020 U.S. Environmental Protec- tion Agency’s cord wood emission limits for wood heaters. Under specific test conditions this heater has been shown to deliver heat at rates rang- ing from 14,200 BTU/hr to 53,600 BTU/hr.”...
CAUTION: To avoid burns or wood splinters, when opening/closing the fuel door or adding wood to the fire, You should always wear appropriate protective gloves to protect your hands from the heat being emitted from this fireplace. F2450M Regency Freestanding Woodstove...
CONNECTOR - MOBILE HOME CONNECTOR - MOBILE HOME ASTM E3053. Modèle Regency F2450M – 2,3 g /h. Cet appareil de chauffage au bois doit être inspecté périodiquement et réparé pour fonctionner correctement. Consulter SIDEWALL A 381 mm / 15 in...
WARNING: ONLY USE SPECIFIED COMPONENTS. The following items are required when assembling your Regency Stove. F2450M unit - the Rear Heat Deflector is supplied with the stove, but if you choose not to use it you must use the Airmate instead...
Loosen the screws on the rear on the stove (3 per Diagram 1 side), slide the side panel up as far as possible and then secure by tightening the screws. Screws Diagram 2 Diagram 3 Diagram 5 F2450M Regency Freestanding Woodstove...
Fibre washer Shown with Classic door Logo Installation 1. Push the Regency logo into 6. Reinstall cover plate if not using ash drawer option. the two holes in the front bottom left corner of 7. Install logo plate onto heat shield by placing in 2 holes as the pedestal cover shown in diagram.
Minimum Alcove Clearance and Clearance to Combustible Materials The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level. Note: Minimum alcove ceiling height - 83" Maximum depth of alcove - 48"...
6. Fasten the raincap with spark screens (if required) to the top of your chimney. 7. To complete your chimney installation, install the double wall connector pipe from the Horizontal Installation stove’s flue collar to the chimney support device. F2450M Regency Freestanding Woodstove...
Maintain proper clearance to the structure as recommended by the manufacturer. The chimney must be the required height above the roof or other obstructions for safety and proper draft operation. The space heater is to be connected to a factory-built chimney conforming to CAN/ULC-S629, Standard for 650 C Factory-Built Chimneys. F2450M Regency Freestanding Woodstove...
24 gage minimum sheet metal supports. See that the supports are fastened securely to wall surfaces on all sides. Make sure fasteners used to secure the metal chimney connector do not penetrate chimney flue liner. F2450M Regency Freestanding Woodstove...
11. WARNING: DO NOT INSTALL IN A SLEEPING ROOM OF A MOBILE HOME. 12. Use silicone to create an effective vapour barrier at the location where the chimney or other com- ponent penetrates to the exterior of the structure. F2450M Regency Freestanding Woodstove...
4 screws. 4 screws Diagram 2 Diagram 5 9. Place unit into position and install the mandatory outside air kit. See «Mobile Home installation» section in this manual. Diagram 3 F2450M Regency Freestanding Woodstove 920-167 28.10.19...
15. Install blanking plate to the front of the pedestal with 4 screws. Use picture from step 8. 16. Install the mandatory outside air kit. See «Mobile Home Instal- lation» section in this manual. Place unit into its final position to complete install. F2450M Regency Freestanding Woodstove 920-167 12.10.19...
Example b) 1000' 18.72' 21.84' 2000' 19.44' 22.68' 5000' 21.60' 25.20' 8000' 23.76' 27.72' WARNING: CAUTION: The structural integrity of the mobile home DO NOT INSTALL IN SLEEPING floor, wall and ceiling/roof must be maintained. ROOM F2450M Regency Freestanding Woodstove...
Mark the position of your unit as outlined in the "General Information" and "Clearances to Combustibles" section of the manual. Pipe fresh air into the pedestal area by using a minimum 4" duct pipe with a mesh grill at the outside termination. Rear View F2450M Regency Freestanding Woodstove...
NOTE: The "AD" brick in the drawings above is the brick covering the Ash Dump hole that is used when the Ash Drawer Kit is installed (refer to the Listed Components for Mobile Home Installation section). F2450M Regency Freestanding Woodstove...
(Refer to Diagram 1) Door hinges Wood handle Door Door handle Hinge Cap Cover Diagram 2 tooltip Diagram 3 919-967a F2450M Regency Freestanding Woodstove 04.03.19...
4 . Install the 2 front secondary air tubes with pliers and hammer to lock them 2. Slide the left baffle over the 2 remaining air tubes from the front and then into place, as shown below. push it to the back. Side View 5. Reverse Step 1. F2450M Regency Freestanding Woodstove...
Wiring errors can cause improper and dangerous operation. Neutral Manual/ Green Live Ground Auto 120V AC Switch Switch 60 Hz Fan Thermodisc (normally open) Black Black Black Ground Wiring Diagram 908-126a 04/08/14 F2450M Regency Freestanding Woodstove...
WARNING: Operation of the unit with out proper installation of smoke deflector will void warranty. Ensure deflector is seated so bolts are situated at the top of the keyhole before tightening. F2450M Regency Freestanding Woodstove...
Primary Air Damper Left - Open Right - Closed WARNING: To build a fire in igno- rance or to disregard the information contained in this section can cause serious permanent damage to the unit and void your warranty!! F2450M Regency Freestanding Woodstove...
If you also have a fireplace to ensure to reach operating temperatures. in your home, a downdraft may be created by your Regency Stove causing a draft down your WARNING: Never build a roaring fire in chimney. If this occurs, slightly open a window a cold stove.
3. Never start a fire if the ash plug and ash drawer are not in place. This will cause over firing which 8. Your Regency stove can be very hot. You may be can cause excessive warping of the stove.
ATE CARBON MONOXIDE AND ARE VERY DANGEROUS. Your Regency stove is supplied with 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact, purchase your replacement from an authorized Regency dealer only.
Door Gasket If the door gasket requires replacement 7/8" diameter material must be used. Regency uses a 7/8" gasket rope (Part #846-570). A proper high temperature gasket adhesive is required. See your Regency Dealer.
NOTE: Chimney Cleaning We highly recommend that the chimney cleaning be done by a professional as they will have the necessary tools such as a proper sized brush and special vacuum cleaner designed to deal with fine particles. F2450M Regency Freestanding Woodstove...
2. Loosen the two 7/16'' bolts + nuts to remove / replace vertical deflector. 3. Repeat steps to install new vertical deflector. NOTE: ENSURE THAT VERTICAL DEFLECTOR IS PUSHED UP AS FAR AS POSSIBLE. TIGHT TO TOP OF FIREBOX. F2450M Regency Freestanding Woodstove...
3 way Switch 850-105 Airmate 075-051 SS Slide Holder 075-073F Tool Hanger 948-223 Regency Logo Plate 910-157/P Fan Motor Only With Squirrel cage 910-142 Fan Thermodisc 021-032/P Vertical Stainless Deflector 021-022 Firebox Floor Gasket N/S = Not Shown F2450M Regency Freestanding Woodstove...
5/16" x 5 1/2 " Long Hex Head Bolt (Each) 820-468F Metal Washer 820-456 Metal Spacer/Support Bracket (Each) Part # Description 021-915 Pedestal Complete 075-069 Pedestal Door 904-257 Magnetic Catch (Each) 075-910 Ashdrawer 904-023 5/16 x 1-1/2 Hex Head Bolt (Each) F2450M Regency Freestanding Woodstove...
Brick - Regular Full Size: 1-1/4" x 4-1/2" x 9" Brick Partial: 1-1/4" x 2" x 4-1/2" Brick Partial: 1-1/4" x 4-1/2" x 3-1/2" Brick Partial: 1-1/4" x 2" x 9" NOTE: This kit contains one spare brick in case of breakage. F2450M Regency Freestanding Woodstove...
At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective prior to processing or authorizing of any claim. Failure to allow this upon request will void the warranty. Revision Date: July 2019 Regency Wood Products Warranty F2450M Regency Freestanding Woodstove...
Page 37
Freight damages for products or parts are not covered under the terms of the warranty. Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. F2450M Regency Freestanding Woodstove Revision Date: July 2019 Regency Wood Products Warranty...
Page 38
Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx...
Page 39
Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.