Installation Check List - Stanley Ardmore Installation And Operating Instructions Manual

Non boiler solid fuel stove
Table of Contents

Advertisement

Flue System
1. Minimum Flue Height of 4.6 metres (15 feet).
2. Appliance should be connected to a minimum of 1.8 metres (6 feet) of 150mm (6")
flue pipe with a horizontal run not exceeding 150mm (6").
3. Appliance should be connected to a chimney of less than 200mm (8") in diameter
(otherwise the chimney must be lined with a 6" flue liner).
4. The chimney venting position must be above the main ridge of the roof or adjacent
outside obstructions.
5. The chimney serving this appliance should not serve any other appliance.
6. Access should be provided to the chimney serving the appliance to allow for cleaning.
Location
7. Clearance to combustible materials must be adhered to as described in the Clearance
to Combustible section.
8. The stove must be installed on a floor protector that covers the area under the stove
and extends 18" to the front & 8" to the sides and back.
Ventilation & Combustion Air Requirements
9. The room in which the appliance is located should have an air vent of adequate
size to support correct combustion (see Building Regulations Part J, Heat producing
appliances for specific details).

INSTALLATION CHECK LIST

18
Tick

Advertisement

Table of Contents
loading

Table of Contents