The page includes the following fields:
General Settings:
Object
Enable Loop
Protection
Transmission Time
Shutdown Time
Port Configuration:
Object
Port
Enable
Action
Tx Mode
Buttons
: Click to save changes.
:
Click to undo any changes made locally and revert to previously saved values.
4.16.2 Status
This page displays the loop protection port status the ports from the Managed Switch.
Description
Controls whether loop protections is enabled (as a whole).
The interval between each loop protection PDU sent on each port. valid values
are 1 to 10 seconds.
The period (in seconds) for which a port will be kept disabled in the event of a
loop is detected (and the port action shuts down the port). Valid values are 0 to
604800 seconds (7 days). A value of zero will keep a port disabled (until next
device restart).
Description
The switch port number of the port.
Controls whether loop protection is enabled on this switch port.
Configures the action performed when a loop is detected on a port. Valid values
are Shutdown Port, Shutdown Port and Log or Log Only.
Controls whether the port is actively generating loop protection PDU's, or
whether it is just passively looking for looped PDU's.
Figure 4-16-2: Loop Protection Status Page Screenshot
352
User's Manual of MGSW-28240F