Download Print this page
Planet MGSW-28240F Quick Installation Manual

Planet MGSW-28240F Quick Installation Manual

24-port 100/1000x sfp + 4-port 10g sfp+ managed metro ethernet switch
Hide thumbs Also See for MGSW-28240F:

Advertisement

24-Port 100/1000X SFP + 4-Port 10G SFP+
Managed Metro Ethernet Switch
MGSW-28240F
Quick Installation Guide

Advertisement

loading

Summary of Contents for Planet MGSW-28240F

  • Page 1 24-Port 100/1000X SFP + 4-Port 10G SFP+ Managed Metro Ethernet Switch MGSW-28240F Quick Installation Guide...
  • Page 2: Table Of Contents

    Table of Contents 1. Package Contents ..................3 2. Requirements ..................... 4 3. Wiring DC Power Inputs ................5 4. Terminal Setup ................... 6 5. Logon to the Console .................. 7 6. Configuring IP Address ................8 7. Starting Web Management .................10 8.
  • Page 3: Package Contents

    1. Package Contents Thank you for purchasing PLANET Managed Metro Ethernet Switch, MGSW-28240F. The term “Managed Switch” mentioned in this Quick Installation Guide refers to the MGSW-28240F. Open the box of the Managed Switch and carefully unpack it. The box should...
  • Page 4: Requirements

    2. Requirements Workstation should be running Windows XP/Vista/7/8, Windows 2003/2008, MAC OS X or later, Linux, UNIX or other platforms compatible with TCP/IP protocols. Workstation should be installed with Ethernet NIC (Network Interface Card) Serial Port Connection (Terminal)  The above workstation should come with COM Port (DB9) Ethernet Port Connection  Network cables - Use standard network (UTP) cables with RJ-45 connectors.  The above PC should be installed with WEB Browser and JAVA runtime envi- ronment Plug-in. It is recommended to use Internet Explore 7.0 or above to access the Managed Switch.
  • Page 5: Wiring Dc Power Inputs

    3. Wiring DC Power Inputs The 6-contact terminal block connector on the rear panel of the MGSW-28240F is used for two DC redundant power inputs. Please follow the steps below to insert the power wire. 1. Insert positive / negative DC power wires into the contacts 1 and 2 for DC POWER 1, or 5 and 6 for DC POWER 2.
  • Page 6: Terminal Setup

    4. Terminal Setup To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to serial (console) port of the Managed Switch. The console port of the Managed Switch is DCE already so that you can connect the console port directly through the PC without the need of Null Modem. PC / Workstation with Terminal emulation software PLANET Managed Switch RS-232...
  • Page 7: Logon To The Console

    Username: admin Password: admin Figure 5-1: MGSW-28240F Managed Switch Console Login Screen 1. F or security reason, please change and memorize the new pass- word after this first setup. 2. O nly accept command in lowercase letter under console inter- Note face.
  • Page 8: Configuring Ip Address

    The Managed Switch is shipped with default IP address as shown below:. IP Address: 192.168.0.100 Subnet Mask: 255.255.255.0 To check the current IP address or modify a new IP address for the Switch, please use the procedures as follows:  Show the current IP address 1. On “MGSW-28240F/>” prompt, enter “show ip”. 2. The screen displays the current IP address, Subnet Mask and Gateway as shown in Figure 6-1. Figure 6-1: Show IP Information Screen...
  • Page 9  Configuring IP address 3. On “MGSW-28240F/>” prompt, enter the following command and press <Enter> as shown in Figure 6-2. MGSW-28240F /> ip setup 192.168.1.100 255.255.255.0 192.168.1.1 The previous command would apply the follow settings for the Switch. IP Address: 192.168.1.100 Subnet Mask: 255.255.255.0 Gateway: 192.168.1.1 Figure 6-2: Set IP Address Screen 4. Repeat Step 1 to check if the IP address is changed. If the IP is successfully configured, the Managed Switch will apply the new IP address setting immediately. You can access the Web interface of the Managed...
  • Page 10: Starting Web Management

    7. Starting Web Management The following shows how to start up the Web Management of the Managed Switch. Note the Managed Switch is configured through an Ethernet connection. Please make sure the manager PC must be set on the same IP subnet address. For example, the default IP address of the Managed Switch is 192.168.0.100, then the manager PC should be set at 192.168.0.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.
  • Page 11 2. When the following dialog box appears, please enter the default username and password “admin” (or the password you have changed via console). The login screen in Figure 7-2 appears. Default Username: admin Default Password: admin Figure 7-2: Login Screen 3. After entering the password, the main screen appears as shown in Figure 7-3. Figure 7-3: Web Main Screen of the Managed Switch...
  • Page 12 4.The Switch Menu on the left of the Web page lets you access all the commands and statistics the Switch provides. Figure 7-4: Switch Menu If you are not familiar with Switch functions or the related param- eter, press “Help” button anytime on the left of the Web page to get the help description.
  • Page 13 To reset the IP address to the default IP Address “192.168.0.100” or reset the login password to default value, press the hardware reset button on the front panel for over 5 seconds. After the device is rebooted, you can login to the management Web interface within the same subnet of 192.168.0.xx. 100~240V AC DC POWER MGSW-28240F Reset DC Input Range: 115200, N, 8, 1 50/60 Hz 36V~72V...
  • Page 14: Customer Support

    PLANET website first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team. PLANET online FAQ : http://www.planet.com.tw/en/support/faq.php?mt=menu_support_1 Switch support team mail address : support_switch@planet.com.tw Copyright © PLANET Technology Corp. 2013. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.
  • Page 15 This page is intentionally left blank...
  • Page 16 This page is intentionally left blank...