External Device Setup, Configuration And Calibration; Radar Configuration, Calibration And Checkout Procedures - Garmin GMX 200 Installation Manual

Hide thumbs Also See for GMX 200:
Table of Contents

Advertisement

The ChartView Activation Card must not be used to store database files,
including NavData, SafeTaxi, FliteChart, and ChartView.
5.4
E xternal Device Setup, Configuration and Calibration
3 1 B
All procedures in this section assume that the GMX 200 has been configured for the applicable external
data sources. The original documentation for the external sensors describes how to calibrate the sensor
using another display – this section describes how those procedures are modified if the GMX 200 display
is used instead.
5.4.1
R ADAR Configuration, Calibration and Checkout Procedures
7 3 B
The following steps are performed to verify the interface between the RADAR sensor and the GMX 200
I/O. The radome should NOT be installed during these tests as visual verification of antenna movement
is required.
Note that the Antenna Receiver/Transmitter should be installed and calibrated in accordance with the
manufacturer's specifications. This manual does not cover the installation or calibration of the actual
ART unit.
Configuration procedures include steps that require the radar antenna to be powered on.
Please observe all safety precautions during these steps including: Do not perform in the
vicinity of refueling operations; Do not perform while personnel are in the vicinity
(approximately 20 feet) of the radar sweep area.
See FAA AC20-68B "Recommended Radiation Safety Precautions For Airborne
Weather Radar" for safety precautions to be taken by personnel when operating airborne
weather radar on the ground.
5.4.1.1
A RT 2000 Calibration Procedures Using GMX 200
9 6 B
Refer to the Bendix/King ART2000 Color Weather Radar System Installation Manual, Revision 4 or
later. Follow the instructions in "Stabilization calibration with Radar Indicator" or its equivalent.
Skip the description in the ART2000 manual on how to enter calibration mode. The GMX 200 allows a
single button push to enter calibration mode. The GMX 200 MUST be in Install mode to calibrate the
radar head. Follow the instructions below.
1. Turn the GMX 200 on.
2. After boot-up is complete, key-in the install sequence 1, 4, 6, on the line select keys to enter the
Install mode.
3. Press the FN key until one of the smart key options is RADAR. If the RADAR option is not
available, ensure that the GMX 200 is configured for a radar source.
4. Press the smart key corresponding to the RADAR option. You will now switch to the Radar page.
5. Press the STBY/ON line select key on the GMX 200 to put the radar unit into standby mode. This
may take up to twenty seconds.
6. Once the radar is in standby mode, one of the menu options will be TEST. Press the TEST key.
7. Once the GMX 200 is in Test mode, press the MENU/ENT key to switch to the Setup page.