Installation Instructions

5" x 8" DVP Direct Vent Termination Kit
Models: DVP-RVTK, DVM-RVTM, DVP-HVTK, DVP-HSFTK, DVP-TRFK
The information in this instruction manual supersedes the
venting information located in the owners manual shipped
with your fireplace.
The following termination kits can only be used with
Vermont Castings Group Direct Vent fireplaces. Check and
verify your fireplace model.
DVP-RVTK Horizontal Kit
1, Termination Cap
1, Adjustable Pipe
4, #8 x 3" Screw
DVP-RVTM Horizontal Termination Cap
4, Termination Caps
16, #8 x 1" Screw
DVP-HVTK Termination Kit
1, Termination Cap
1, Firestop, 3" (rectangular)
1, Adjustable Pipe
8, #8 x 1" Screw
DVP-HSFTK Flex Horizontal Termination Kit
1, Termination Cap
1, Flex Adapter Starter (5" inner /8" outer)
1, Flex Adapter, 5"
1, Flex 5" x 48"
2, Clamp, 5"
4, #8 x 1" Screw
4, #8 x 3" Screw
DVP-TRFK Through the Roof Termination Kit
1, Vertical Termination Cap
1, Storm Collar
1, Flex Adapter Starter (5" inner/8" outer)
1, Flex Adapter, 5"
1, Roof Support
2, Clamps, 8"
24, #10 x 1/2" Self-tapping Screws
3, Springs, 8"
1, Firestop, 1" (square)
4, #8 x 1" Screw
4, Firestop, 1" (square)
16, #8 x 3" Screw
1, Firestop, 1" (square)
1, 90° Elbow
8, #8 x 3" Screw
1, Firestop, 1" (square)
1, Flex Adapter, 8"
1, Flex 8" x 48"
2, Clamp, 8"
24, #10 x 1/2" Self-drilling Screw
3, Spacer Springs
1, Rigid Pipe, 2'
1, Flex Adapter, 8"
2, Clamps, 5"
6, Wood Screws, 2"
1, Spacer
Addendum
CAUTION
All Vermont Castings Group Direct Vent Fireplaces have
been tested and approved to ANSI / CSA Standards and
will operate safely when installed in accordance with this
instruction manual. Read all instructions before starting
installation, then follow these instructions carefully to
maximize fireplace performance and safety. Report
damaged parts to your dealer.
WARNING
Always maintain minimum clearances around vent
systems. Rear/Top Vent Vertical Side wall: Horizontal
sections of this vent system require a minimum of 3"
(76 mm) clearances to combustibles at the top of the
flue and 1" (25 mm) clearance at the sides and bottom
until the flue penetrates the outside wall. A minimum 1"
clearance all around the flue is acceptable at this point
of penetration. If vertical rise is 7
when top venting, the clearance to combustibles is 1" on
all sides of the horizontal run. FOR VERTICAL RUNS
ONLY, maintain a 1" (25 mm) minimum clearance to
all sides. Do not pack the open air spaces around the
fireplace or flue with insulation or other materials. Any
horizontal run must have a 1/4" rise for every one (1)
foot of run towards the vent termination. Never run the
vent level or down.
WARNING
• Any common venting of this gas appliance with other
gas appliances is not allowed.
• Do not connect this appliance to a chimney flue
servicing a separate solid fuel-burning appliance.
WARNING
Failure to follow these instructions may create a possible
fire hazard and will void the warranty.
feet (2.3 m) or higher
1
2
20307393 Rev 1 0315