WDV Series Gas Fireplace

ELECTRICAL WIRING

General
1. This fireplace is equipped with the Signature Control
valve which operates on 6 volts. The A/C module plugs
into the fireplace junction box A/C power supply. Four (4)
"AA" batteries are used for back up during power outages.
2. The Signature Command System can also be operated
without A/C power. The system can run on four (4) "AA" bat-
teries for approximately six (6) months under normal use.
3. A/C power must be used to power the A/C module, blow-
ers, lights and AUX accessories used with this fireplace.
Optional Accessory Requirements
1. This fireplace may be used with a wall switch
and/or Signature Command wireless controls.
2. The command center control may be mounted on the wall
with the use of the SCSWEK 15ft. wall mount extension kit.
Pressure Outlet
Figure 33 -
Signature Command Valve
Electrical connections should only
be performed by a qualified, licensed
FP1909a
electrician. Main power must be off when
connecting to main electrical power supply
signature command valve
or performing service. All wiring shall be
alternate view
in compliance with all local, city and state
codes. The appliance, when installed, must
8/08
be electrically grounded in accordance with
local codes or in the absence of local codes,
with the National Electrical Code ANSI/NFPA
70 (latest edition) and Canadian Electrical
Code, CSA C22.1.
Label all wires before disconnecting when
servicing controls. Wiring errors can cause
improper and dangerous operation.
24

JUNCTION BOX WIRING

1. This should be done before framing the fireplace. Wire
2. Remove the external junction box cover by removing
3. The junction box cover has a factory installed "romex"
Pressure Inlet
FP1909a
Pilot
Adjustment
Screw
the receptacle into an electrical circuit. Wire with mini-
mum 60° C wire in accordance with prevailing codes.
the screw from the side of the outside firebox wall.
Junction box was installed at the factory.
style strain relief connector. After connecting the wires,
route the wire leads through this connector. Refer to the
wiring diagram in Figure 34.
Junction Box
Figure 34 -
Junction Box Wiring Diagram

COMMAND CENTER WALL INSTALLATION

The command center may be mounted on the wall with the
FP1912
use of the SCSWEK Kit (15ft. cable, junction box, wall cover).
Junction box wiring
Mount the junction box provided at the desired
location on the wall. Do not extend beyond the 15 ft.
8/08
wire cable provided. If a longer distance is required,
the 15 ft. may be extended up to 30 ft. maximum by
using two (2) SCSWEK cables plugged together.
Route the wire from junction box to lower control area
at bottom of fireplace. Unplug the 12" cable from the
command center. Attach the connector to the pins from
wire by pushing in to connector making sure to follow the
color code on connector. Plug the 15 ft. extension cable
into the 2 ft. cable. Remove command center from the
fireplace and plug the other end of the extension cable
into the command center. Snap on wall cover provided
and screw to junction box.

WALL SWITCH INSTALLATION

The wall switch wire connection is located off the 2 ft.
wire harness from the control box to the command center.
Figure 35. The connection is labeled "Wall Switch".
Unplug the male and female connectors and connect the
two (2) low voltage wires provided. Run wire to desired
location on wall. Up to 50 ft. of 18 ga. wire may be used
if necessary. Attach wires to wall switch. Mount the wall
switch in to junction box and screw on cover.
Do not connect wall switch to 110 V
circuit.
FINAL INSTALLATION
120V AC
60Hz
Factory Supplied
Not Supplied
20306744