Ras-18Ufpx-T2 / Ras-18Uax-T2 - Toshiba RAS-18UFHP-E Service Manual

Under ceiling / console type
Hide thumbs Also See for RAS-18UFHP-E:
Table of Contents

Advertisement

5-4. RAS-18UFPX-T2 / RAS-18UAX-T2

0.39m
(Connecting pipe)
∅15.88 mm
0.39m
(Flexible pipe)
∅15.88 mm
O.D.:15.88 mm
Packed valve
(∅15.88)
Compressor
PH210T2-4L7
50Hz
Standard
Cooling
High temperature
Low temperature
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Multi blade fan
P
Condenser
Muffler
Propeller fan
Outdoor unit
Standard
pressure P
(MPaG)
0.4
0.5
0.3
T
Indoor unit
Evaporator
Surface temp. of heat
exchanger interchanging
pipe T (°C)
10.0
13.0
2.0
– 21 –
FILE NO. SVM-02008
0.49m
(Connecting pipe)
∅6.35 mm
O.D.:6.35 mm
Packed valve
(∅6.35)
Capillary tube
∅2.0x800S
Refrigerant
R-22 1.47 kg
Mark (
) means check points of Gas Leak
Ambient temp.
conditions DB/WB
Fan speed
(indoor)
Indoor
High
27/19
High
32/23
Low
21/15
(°C)
Outdoor
35/24
43/26
21/15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents