Specification Of Electrical Parts; Indoor Unit; Ras-10Ukhp-As2); Outdoor Unit (Ras-13Uah-Es2, Ras-13Uah-As2, Ras-13Ua-Es2, Ras-13Ua-As2) - Toshiba RAS-13UKHP-ES2 Service Manual

Table of Contents

Advertisement

4. SPECIFICATION OF ELECTRICAL PARTS

4-1. Indoor Unit (RAS-13UKHP-ES2, RAS-13UKHP-AS2, RAS-10UKHP-ES2,

RAS-10UKHP-AS2)

No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
Switching transformer (T01)
4
Microcontroller unit (IC30)
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Bridge rectifier (DB01)
8
Capacitor (C02)
9
Fuse (F01)
10
Varistor (R21, R22)
11
Resistor (R01)
12
Louver motor
13
Relay (Comp., RY01)
14
Relay (Fan, RY03)
15
Relay (Solenoide, RY04)

4-2. Outdoor Unit (RAS-13UAH-ES2, RAS-13UAH-AS2, RAS-13UA-ES2, RAS-13UA-AS2)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Solenoid coil
5
(for 4-way valve)
(for Heat pump model)
Type
MMF-240-20-4A-1
———
SWT-47
TMP87CM40AN
———
LC*SS11V-06270
D3SBA60
KMH400VSSN47M22S
TSCR6.3A
15G561K
RF-2TK5R6
MP24GA
DI12D1
G5N-1A
G5N-1A
Type
Output (Rated) 1100W, 2poles, 1 phase, 220 – 240V, 50Hz
PA150X2T-4FM1
Winding resistance (Ω)
(at 20°C)
Output (Rated) 42W, 6poles, 1 phase, 220 – 240V, 50Hz
HF-240-42B
Winding resistance (Ω)
(at 20°C)
DS45115CBPQC AC 450V, 1.5µF
DS371306CPN
AC 370V, 30µF
VHV-01AJ503C1
AC 220 – 240V, 50Hz
– 12 –
FILE NO. SVM-03001
Specifications
AC Motor with 135°C thermo fuse
10kΩ at 25°C
10kΩ at 25°C
27mH, 600mA
4A, 600V
47µF, 400V
T6.3A, 250VAC
560V
5.6Ω, 2W
12VDC
Rating 20A/AC250V, 12VDC
Rating 3A/AC250V, 12VDC
Rating 3A/AC250V, 12VDC
Specifications
C-R
2.49
Red-Black
176.2
C-S
3.95
White-Black
290.5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents