Toshiba RAS-18UFHP-E Service Manual page 67

Under ceiling / console type
Hide thumbs Also See for RAS-18UFHP-E:
Table of Contents

Advertisement

9-8-3. How to check outdoor P.C. board
When the check code is detected on the outdoor unit, the following lamps are indicated on the LED display and
the Dip switch (DSW01).
Dip
switch
ON
Table 1
1
2
ON
Table 2
1
2
• When the lamps (1 to 4) on the LED are indicated in order, the phase detecting protection circuit operates
regardless of the Dip switch setting.
18
D20
D22
RB03 R91
R93 R92
LED
LED
Dip switch
1
2
3
4
ON
1
2
ON
As
follows
1
2
: The lamp is indicated.
Table 9-8-3 LED display and check code
1 Red
Timer short
20 Power line
18 Thermo sensor
(TE) circuit
19 Heat exchanger
sensor (TD) circuit
1
Indication exchange
2
D23
Dip switch (SW01)
D40
D44
D41
D24
D45
D42
D25
D46
D43
Q60
D26
D47
8
CN16
+5V
CN28
CN29
R64 C
D04 Orange
CN17
CN18
CN19
C64
Serial receiving LED
R65
22
D07
1
2
D08
R22
D09
3
R23
D05 Green
D10
Serial transmitting LED
Fig. 9-8-1 Dip switch and LED
Table 9-8-4
Normal operation
Timer short operation
20
Power line protective circuit
1E
Heat exchanger sensor (TD) temperature rise protection
21
IOL operation
18
Thermo sensor (TE) circuit
19
Heat exchanger sensor (TD) circuit
Normal operation
Protective operation : Once
Protective operation : Twice
Protective operation : Three times
Protective operation : Four times (Emergency stop)
18
Thermo sensor (TE) circuit
19
Heat exchanger sensor (TD) circuit
1E
Heat exchanger sensor (TD) temperature rise protection
21
IOL operation
LED status
: The lamp blinks fast.
LED
2 Yellow
3 Yellow
protective circuit
Protective operation frequency for sensor
circuit error
Schematic Diagram of
Outdoor Control Board
Check contents
: The lamp blinks slow.
– 66 –
FILE NO. SVM-02008
4 Yellow
1E Heat exchanger
sensor (TD) temp.
rise protection
21 IOL operation
circuit
All off
All off
: The lamp is not indicated.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents