YES
Are all of compressor
cords normal?
YES
Is compressor motor
winding normal?
(Check winding resistor.)
YES
Is capacitor for
compressor normal?
YES
Is overload relay normal?
YES
Does compressor start?
YES
Does compressor stop
after a while?
YES
Is gas quantity normal?
(Check gas pressure.)
YES
Compressor is defective.
YES
Replace P.C. board.
NO
NO
Compressor is
defective.
NO
Capacitor is
defective.
NO
Overload relay is
defective.
NO
Compressor is
defective.
NO
Gas shortage
(Gas leak)
– 62 –
FILE NO. SVM-02008
Rewire or replace
defective cords.
Replace compressor.
Replace capacitor.
Replace overload relay.
Replace compressor.
Supply gas.