8-4-5. Console installation
• Select the terminal of Selector-SW from [C position] to
[F position].
Fig. 8-4-18
<Cutting a hole and mounting the installation plate>
• When installing the rear piping, determine the pipe
hole position, drill the pipe hole (∅80 mm) at a slight
downward slant to the outdoor side.
• For mounting of the Installation plate 1, use the Paper
pattern, which is inside the package box cover.
1093
742
Floor
Fig. 8-4-19
5 mm dia. hole
Clip anchor
(local parts)
Fig. 8-4-20
CAUTION
Failure to firmly install the unit may result in personal
injury and property damage if the unit falls.
• In case of block, brick, concrete or similar type walls,
make 5 mm dia. holes in the wall.
• Insert clip anchors for appropriate Mounting screws 8.
NOTE:
• Secure four corners and lower parts of the Installation
plate 1 with 6 to 8 mounting screws to install it.
375 mm
or more
140
Rear piping hole. ∅80
Anchor bolt
Projection
15 mm or less
8
8
8 Mounting
8
8
screw
∅4 x 25 s s s s s
<Install the indoor unit>
• Install the Installation plate 1 at the wall according to
the Paper pattern .
• Hang the indoor unit on the hooks of the Installation
plate 1.
• Fix the lower portion of the indoor unit with Mounting
screws 8 (2 places).
8
8
8
8 Mounting screw
8
<Condition for installation>
• The unit must not decline more than 15 mm in either
axis.
15 mm
– 42 –
FILE NO. SVM-02008
Indoor unit
Hook
1 Installation
1
1
1
1
plate
8 Mounting screw
8
8
8
8
Fig. 8-4-21
Fig. 8-4-22