Install the storage controller.
9.
Connect all necessary internal cables to the storage controller. For internal drive cabling information,
10.
see "Storage cabling (on page 88)."
Install the PCI riser cage (on page 24).
11.
Install the access panel (on page 22).
12.
Install the server into the rack
13.
Connect all necessary external cables to the storage controller. For more information on these cabling
14.
requirements, see the documentation that ships with the option.
Power up the server (on page 17).
15.
CAUTION:
all bays are populated with either a component or a blank.
Install the drives
16.
For more information about the integrated storage controller and its features, select the relevant user
documentation on the HP website (http://www.hp.com/go/smartstorage/docs).
To configure arrays, see the HP Smart Storage Administrator User Guide on the HP website
(http://www.hp.com/go/smartstorage/docs).

Installing an FBWC module and an HP Smart Storage Battery

For more information about product features, specifications, options, configurations, and compatibility, see
the product QuickSpecs on the HP website (http://www.hp.com/go/qs).
CAUTION:
powered down and the last to be powered back up. Taking this precaution ensures that the system
does not erroneously mark the external drives as failed when the server is powered up.
To install the component:
Power down the server (on page 17).
1.
Remove all power:
2.
("Installing the server into the
To prevent improper cooling and thermal damage, do not operate the server unless
("Drive
options" on page 37).
In systems that use external data storage, be sure that the server is the first unit to be
rack" on page 30).
Hardware options installation 43