Electrical system
Specific tooling
020333Y Single battery charger
020334Y Multiple battery charger
WARNING
BATTERY ELECTROLYTE IS TOXIC AND IT MAY CAUSE SERIOUS BURNS. IT CONTAINS SUL-
PHURIC ACID. AVOID CONTACT WITH YOUR EYES, SKIN AND CLOTHING. IF IT ACCIDENTALLY
COMES INTO CONTACT WITH YOUR EYES OR SKIN, WASH WITH ABUNDANT WATER FOR
APPROX. 15 MIN. AND SEEK IMMEDIATE MEDICAL ATTENTION.
IF ACCIDENTALLY SWALLOWED, IMMEDIATELY DRINK LARGE QUANTITIES OF WATER OR
MILK FOLLOWED BY MAGNESIUM MILK, BEATEN EGG OR VEGETABLE OIL. SEEK IMMEDIATE
MEDICAL ATTENTION.
BATTERIES PRODUCE EXPLOSIVE GASES; KEEP CLEAR OF NAKED FLAMES, SPARKS OR
CIGARETTES; VENTILATE THE AREA WHEN RECHARGING INDOORS.
ALWAYS WEAR EYE PROTECTION WHEN WORKING IN THE PROXIMITY OF BATTERIES.
KEEP OUT OF THE REACH OF CHILDREN.

1) Battery preparation

Position the battery on a flat surface. Remove the
adhesive sheet closing cells and proceed as quick-
ly as possible to run the subsequent activation
phases.

2) Electrolyte preparation.

Remove the container of the electrolyte from the
pack. Remove and preserve cover strips from the
container, in fact, the strip will later be used as a
closing cover.
Note: Do not pierce the sealing of the container or
the container itself because inside there is sulphu-
ric acid.

3) Procedure for filling the battery with acid.

Position the electrolyte container upside down with
the six areas sealed in line with the six battery filler
holes. Push the container down with enough force
to break the seals. The electrolyte should start to
flow inside the battery.
Note: Do not tilt the container to prevent the flow
of electrolyte from pausing or stopping.
4) Control the flow of electrolyte