Leak testing of the appliance shall be conducted according to the manufacturer's instructions.
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during
any pressure testing of that system in excess of 3.5kPa.
Maximum inlet gas supply pressure 5 kPa
After installing the gas supply and making all connections, check thoroughly for possible leaks:
1 Turn all control dials on unit to "OFF" position.
2 Open the valve on the gas supply.
3 Using a leak detection fluid, check each gas connection one at a time by spraying or brushing the solution over
the connection. The presence of bubbles will indicate a leak.
4 If necessary, tighten the fitting and recheck for leaks.
5 Turn on burner valve and light each burner.
6 Check for a clear blue flame without yellow tipping. If burners show any abnormalities, check that they are
located properly and in line with the injector.