!1
SECURE TO COUNTERTOP WITH BRACKETS BASED ON THE COUNTERTOP THICKNESS
Place the cooktop into the cutout and
tighten it with the supplied clamps. These
will cope with the countertop thicknesses
19 - 50 mm when used in the two
orientations shown.
IMPORTANT! - Do not over tighten.
Make sure the connection point will be accessible with the cooktop installed.
●
To enable the gas supply to be readily shut off by the customer, make sure the connection is fitted with an isolating valve
●
close to the cooktop.
A manual shut-off valve must be installed in an accessible location in the gas line external to the appliance for the purpose
●
of turning on or shutting off gas to the appliance.
Gas connection to the product must use the nipple supplied with a 1/2" BSP external thread. The supplied gas pressure
●
regulator must be installed where it will be accessible for adjustment.
If connecting the gas with a flexible hose
Ensure the hose is long enough to allow for removal of cooktop for servicing.
●
Make sure the connector is located as shown in step 5 CLEARANCE DIMENSIONS.
●
The hose assembly must be with an Rp 1/2" (ISO 7-1) female thread connection (AS/NZS 1869 Class B or D certified).
●
The hose assembly must be as short as practicable and comply with the relevant AS/NZS5601.1 requirements.
●
The hose must not be kinked, subjected to abrasion or permanently deformed.
●
The hose must not be near or in contact with any hot surfaces (e.g. base of metal hotlplate, flue, or chassis of
●
undercounter oven etc.)
19 mm - 50 mm
!2
GAS CONNECTION
REPEAT ON ALL THE OTHER SIDES
(Total 6 brackets)
on
NG
Arrow
Adjust to obtain a test point
pressure of 1 kPa with all the
burners operating at highest
setting.
LPG
Make sure the supply pressure
is regulated to 2.75 kPa, with all
the burners operating at highest
setting.
8