Leak testing of the appliance shall be conducted according to the manufacturer's instructions.
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during
any pressure testing of that system in excess of 3.5mbar.
Maximum inlet gas supply pressure 50 mbar.
After installing the gas supply and making all connections, check thoroughly for possible leaks:
1 Turn all control dials on unit to "OFF" position.
2 Open the valve on the gas supply.
3 Using a leak detection fluid, check each gas connection one at a time by spraying or brushing the solution over
the connection. The presence of bubbles will indicate a leak.
4 If necessary, tighten the fitting and recheck for leaks.
5 Turn on burner valve and light each burner.
6 Check for a clear blue flame without yellow tipping. If burners show any abnormalities, check that they are
located properly and in line with the injector.
10
!3

LEAK TESTING

To check that the ignition system operates correctly, light each burner by itself, then all burners in combination.
Check for a well de ned blue ame without any yellow tipping.
If any abnormality is evident, check that the components of the burner assembly are located properly
If proper operation cannot be obtained, contact your nearest F&P Authorised Service Centre.
The cooktop must not be used by the customer until proper operation has been achieved.
lifting o
yellow tip
good ame
diameter of 10 mm and comply with relevant AS 5601/NZS 5261 requ
The hose must not be kinked, subjected to abrasion or permanently d
The hose must not be near or in contact with any hot surfaces
(e.g. base of metal hotlplate, ue, or chassis of underbench oven etc.)