4.18.2 RMON Alarm Status

This Page provides an overview of RMON Alarm entries. Each Page shows up to 99 entries from the Alarm table, default being
20, selected through the "entries per Page" input field. When first visited, the web Page will show the first 20 entries from the
beginning of the Alarm table. The first displayed will be the one with the lowest ID found in the Alarm table; screen in
4-18-2
appears.
The Page includes the following fields:
Object
 ID
 Interval
 Variable
 Sample Type
 Value
 Startup Alarm
 Rising Threshold
 Rising Index
 Falling Threshold
 Falling Index
Buttons
: Click to refresh the Page immediately.
Auto-refresh
:
Check this box to refresh the Page automatically. Automatic refresh occurs every 3 seconds.
:
Updates the table, starting from the first entry in the Alarm Table, i.e. the entry with the lowest ID.
: Updates the table, starting with the entry after the last entry currently displayed.
Figure 4-18-2: RMON Alarm Overview Page Screenshot
Description
Indicates the index of Alarm control entry.
Indicates the interval in seconds for sampling and comparing the rising and
falling threshold.
Indicates the particular variable to be sampled
The method of sampling the selected variable and calculating the value to be
compared against the thresholds.
The value of the statistic during the last sampling period.
The alarm that may be sent when this entry is first set to valid.
Rising threshold value.
Rising event index.
Falling threshold value.
Falling event index.