3-2. Error Messages
Error messages
Code
Message indicated on
time data display area
01.
REEL TROUBLE-1
02.
REEL TROUBLE-2
03.
REEL TROUBLE-3
04.
REEL TROUBLE-4
05.
REEL TROUBLE-5
06.
TAPE TENSION ERROR
07.
CAPSTAN TROUBLE
08.
DRUM TROUBLE
09.
TH/UNTH MOTOR
TIME OUT
0A.
THREADING TROUBLE
10.
DEW DETECTED
11.
TAPE TOP/END SENSOR
TROUBLE
12.
TAPE TOP SENSOR
TROUBLE
13.
TAPE END SENSOR
TROUBLE
14.
FAN MOTOR TROUBLE
20.
CASSETTE COMPART-
MENT MOTOR LOCK
21.
REEL SHIFT MOTOR
LOCK
22.
REEL POSITION SENSOR
TROUBLE
92.
INTERNAL INTERFACE
93.
CPU INITIALIZE ERROR
97.
SV NV-RAM TROUBLE
A0.
READ WRITE ERROR
A1.
SY ROM ERROR
A2.
DR NV-RAM CHECK
SUM ERROR
A3.
SYS NV-RAM CHECK
SUM ERROR
A4.
PLAYER CONTROLL
COMMAND BUFFER FULL
A5.
RS422 REMOTE
COMMAND BUFFER FULL
B0.
DT HARD ERROR
B1.
TCG HARD ERROR
3-2
Page
Content
3-3
Detected "tape slack" during threading or unthreading.
3-4
Detected " tape slack" during search, fast-forward or rewind.
3-6
Detected "tape slack" during recording or playback.
3-7
Detected abnormal speed of tape running during fast-forward or rewind.
3-8
Detected abnormal operation on S-side or T-side reel during cassette compartment
operation, or detected abnormal current flow in the S-side or T-side mechanism.
3-9
Detected excessive tape tension during playback or recording.
3-10
Detected abnormal operation of capstan motor.
3-10
Detected abnormal operation of drum motor.
3-11
Detected abnormal operation during threading or unthreading.
3-12
Detected incorrect ending of process for tape top when threading.
3-12
Detected dew condensation.
3-13
Detected tape top and tape end simultaneously.
3-13
Detected abnormal condition in tape top sensor.
3-14
Detected abnormal condition in tape end sensor.
3-14
Detected abnormal operation of fan motor for cooling.
3-15
Detected abnormal condition during cassette compartment operation.
3-15
Detected abnormal condition during movement of reel tables in accordance with
cassette sizes.
3-16
Detected L cassette and S cassette positions of reel tables simultaneously.
3-17
Detected abnormal condition in communication between CPUs on circuit boards.
3-18
Detected abnormal condition in mutual check between CPUs at power ON.
3-19
Detected abnormal condition during data-read process of servo system adjustment data
at power ON.
3-19
Detected abnormal condition during data-write process to a RAM on SS-88 board at
power ON.
3-20
Detected abnormal condition during data-read process from ROM in system control
block at power ON.
3-20
Detected abnormal condition during read process of model data at power ON.
3-21
Detected abnormal condition during read process of menu set up data at power ON.
3-21
Transmission buffer of 9-pin serial communication for player control becomes full.
3-22
Received buffer of 9-pin serial communication becomes full.
3-22
Detected abnormal condition during distortion erasure process of DT head.
3-22
Hardware error in time code generator IC and its periphery.