5-1. Periodic Inspection
5-1-3. Hours Meter
This unit displays an hours meter on its SET-UP screen on the control panel.
It is recommended that periodic inspections be carried out using this hours meter as a reference.
1. Method of Display
(1) Press the [SETUP] button at the side of the display.
(2) Press the [F6] (VTR SETUP) button.
(3) The hours meter will be displayed. (VTR SETUP screen)
To end the menu, press the [F10] (EXIT) button.
2. Contents of Display
Menu No.
Item
H01
OPE HOURS
H02
DRUM HOURS
H03
TAPE HOURS
H04
THREAD COUNT
H12
DRUM HOURS r
H13
TAPE HOURS r
H14
THREAD COUNT r
<Example of Display>
C H . C O N D
H O U R S C O U N T E R
N E X T
H 0 1 : O P E H O U R S
C A T E G
H 0 2 : D R U M H O U R S
H 0 3 : T A P E H O U R S
H 0 4 : T H R E D C O U N T -
H 1 2 : D R U M H O U R S r -
H 1 3 : T A P E H O U R S r -
H 1 4 : T H R E D C O U N T r -
0 0 1 : P R E R E A D
0 0 2 : R E C I N H
0 0 3 : R E C I N H A R E -
0 0 4 : C A P L O C K
C H A N G E
D A T A
5-4
Contents
Accumlated power ON time
Accumlated drum rotating hours in the threading end state
Accumlated tape running hours during the F.FWD, REW,
PLAY, SEARCH, REC, EDIT modes (excluding STILL mode)
Accumlated number of threading/unthreading cycle
Accumlated drum rotating hours by threading after resetting
Accumlated tape running hours during the F.FWD, REW, PLAY,
SEARCH, REC, EDIT modes (excluding STILL mode) after
resetting
Accumlated number of threading/unthreading cycle after
resetting
V T R S E T U P
C T L
0 : 0 0 : 0 0 : 0 0
-
1 0 7
-
9
-
8
1 9 4
9
8
1 9 4
-
o f f
-
o f f
a l l
-
2 F D
S A V E /
E X I T
Display
Total is displayed in one hour step
Total is displayed in one hour step
Total is displayed in one hour step
Total number of actual number
of cycle is displayed
Total is displayed in one hour step
Total is displayed in one hour step
Total number of actual number
of cycle is displayed
HDW-F500E MMP1