Note: To obtain optimal results make sure the venting system, heat exchanger and
exhaust channels are cleaned before performing any setting changes.

6.1.7 Combustion Settings and Pilot Settings depending on Fuel Quality

6.1.7.1
PILOT ADJUSTMENT (Pilot Settings Adjustment)
The "PILOT ADJUSTEMENT" will allow you to modify default settings by ± 2 for auger
motor 1 and ± 10 for combustion and exhaust fan, but will only apply during pilot cycle:
To restore default setting, select "DEFAULT".
6.1.7.2
COMBUSTION ADJUSTMENT (Fuel Quality Adjustment)
The "COMBUSTION ADJUSTMENT" will allow you to modify default settings by ± 2 for
auger motor 1 and ± 10 for combustion and exhaust fan.
To restore default setting, select "DEFAULT".
Here are some situations where you may want to adjust these components:
Average speed of auger motor #1:
You may want to increase the auger motor #1 speed if fire goes out when combustion
level is at its minimum setting. When burning poor quality pellets you may also need to
reduce the auger motor speed to avoid unburned pellets to fall into the ash drawer at any
combustion level.