United States:
• Not Less than 36'' (91 cm) above any forced air inlet located within 10 feet (305 cm);
• Not Less than 48'' (122 cm) below and horizontally from, or one foot (30 cm) above,
any door, window or gravity air inlet into any building (See Section 4.4.1.1: Direct
Vent System (2-in-1 Exhaust and fresh air intake);
• Not Less than 24'' (61 cm) from an adjacent building and not less than 84'' (213 cm)
above grade when located adjacent to a public walkway.
• Cannot be located less than 12 inches (300mm) above grade.
• Cannot be located above a gas meter/regulator within 3 feet (900mm) horizontally of
the vertical center line of the regulator.
• Not within 6 feet (1.8 meters) of a gas service regulator vent outlet.
• Other restrictions may apply. See NFPA 211 for further information.
4.4.1.1
Direct Vent System (2-in-1 Exhaust and fresh air intake)
When the stove is installed with a direct vent system, the exit terminal shall be located at
least 9" (23 cm) away from a window or door.
The bottom of the exhaust terminal and air intake must be located at least 1" (30 cm)
above the ground.

4.5 Installation Configurations

4.5.1 Installation Warnings, Cautions and Recommendations Reminder

• PROFESSIONNAL INSTALLATION IS HIGHLY RECOMMENDED
• THIS STOVE USES A PRESSURIZED VENTING SYSTEM. ALL VENT CONNECTOR
JOINTS MUST BE SEALED AND FASTENED. YOU MAY USE RTV SILICONE
(ROOM TEMPERATURE VULCANISATION), METALLIC TAPE, AND A MINIMUM
OF THREE SELF-TAPING SCREWS AT ALL JOINT CONNECTIONS TO ENSURE A
TIGHT SEAL. CONSULT THE PELLET VENT MANUFACTURER'S INSTRUCTION
TO ENSURE PROPER INSTALLATION, CONSISTENT PERFORMANCE, AND TO
AVOID SMOKE AND ASH SPILLAGE.
• THE CHIMNEY CONNECTOR SHALL NOT PASS THROUGH AN ATTIC OR ROOF
SPACE, CLOSET OR SIMILAR CONCEALED SPACE OR FLOORS OR CEILING.
• INSTALL VENTING SYSTEM AT CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
• THE USE OF A SPARK ARRESTER AT THE END OF THE TERMINATION IS
MANDATORY. IT IS IMPORTANT THAT THE SPARK ARRESTER BE CLEAR OF
ANY DEBRIS AT ALL TIME.