To validate the status of a component, you need to go to the "TROUBLESHOOT" page
from the Main Status Page. Once there you will be able to navigate with the arrows at the
bottom page.
Access to
program
VX.XX(
X)
VX.XX
X:XX:X
X
X:XX:X
XX°F
XX°
F
Page 1 provides information on the software version of the stove's two electronic cards. In
addition, you have the total number of hours your stove has been in operation, the
temperature of the exhaust gases and the maximum temperature that your stove has
reached.
Pages 2 and 3 will give you statistics on the number of times a specific error message has
occurred.
From page 4 is the list of operating states of the electronic components. If the square is
green, it means that the operating state of the component is normal, no matter if it's on the
left column or right. If the square is red, it means that there is a security function in
operation. For example, if the stove is off, it is supposed to be cool. If the stove is off but
the temperature probe is warm, the auger motor 2 and the exhaust blower will be running.
This screen will give you the operating status in real time, meaning that when the stove is
running, if a state change occurs, you will see it immediately.
WITH GREEN ICONS
WITH RED ICONS
54
The signal sent to the gear motor 1 is open so the motor
doesn't turn. This state is normal.
The signal sent to the gear motor 2 is closed so the
motor turns. This state is normal.
The signal sent to the gear motor 2 is closed so the
motor turn. This state shows that there is a security
element that prevents it from stopping.