Connection Of The Auxiliary Battery System (Optional); Clearances To Combustible Material - Drolet Edison Installation And Operation Manual

Table of Contents

Advertisement

Edison Installation and Operation Manual
STEP 5
I
USB CONNECTOR
J
USB CABLE GROMMET

2.4 Connection of the Auxiliary Battery System (Optional)

If your stove is equipped with the auxiliary battery system, see Appendix C: Battery
Holder kit (AC01452) and Optional 24V (2X 12V) battery kit (AC01454) to connect it to
the stove.

3 Clearances to Combustible Material

The clearances shown in this section have been determined by tests according to
procedures set out in safety standards ULC S627 (Canada), ASTM E1509 (U.S.A) and
UL1482 (U.S.A). When the pellet stove is installed so that its surfaces are at, or beyond,
the minimum clearances specified, combustible surfaces will not overheat under normal
and even abnormal operating conditions.
WARNING: NO PART OF THE STOVE MAY BE LOCATED CLOSER TO
COMBUSTIBLES THAN THE MINIMUM CLEARANCES SPECIFIED ON THE
CERTIFICATION LABEL.
CAUTION: NO PART OF THE PELLET VENT SYSTEM MAY BE LOCATED CLOSER
TO COMBUSTIBLES THAN THE MINIMUM CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
CAUTION: DO NOT USE MAKESHIFT MATERIALS OR MAKE ANY COMPROMISES
WHEN INSTALLING THIS STOVE.