In order for data in a Unit to be backed up, that Unit must support the simple backup function. Refer to
the operation manual for the specific Unit to check whether this function is supported.
Applicable Units
Serial Communica-
tions Units
FL-net Units
DeviceNet Units
CompoNet Units
Motion Control Units
Position Control
Units
EtherNet/IP Unit
Precautions for Correct Use
Precautions for Correct Use
When using a simple backup file to restore data, use a CPU Unit of the same model as the
backup source. If a CPU Unit of a different model is used, the following operations will result.
• If the number of EM banks for the simple backup file is greater than that of the CPU Unit where
the data is to be restored, the data will not be restored.
• If the number of EM banks for the simple backup file is less than that of the CPU Unit where
the data is to be restored, the data in the EM bank areas in the simple backup file will be
restored, but forced status will not be restored. In addition, EM banks that are not in the simple
backup file will retain their values from before the restoration.
CJ2 CPU Unit Hardware User's Manual
Model numbers
Data backed up for simple backup
CJ1W-SCU21
Protocol macro data (Including both stan-
dard system protocols and user-defined
CJ1W-SCU41
protocols from the flash memory in the
CJ1W-SCU21-V1
Unit or Board)
CJ1W-SCU31-V1
CJ1W-SCU41-V1
CJ1W-FLN22
Data link tables
CJ1W-DRM21
Device parameters (all data in EEPROM in
the Unit)
(Although this is the same data as is
backed up from the Memory Card backup
function supported by the Unit or the
DeviceNet Configuration (Ver. 2.@), there
is no file compatibility.)
CJ1W-CRM21
• Registration tables
• Software settings
• Network parameters
• Slave parameters
CJ1W-MCH71
• Positioning data
• System parameters
• G-language programming
CJ1W-NCF71
• Common parameters
• Individual axis parameters
CJ1W-
• Axis parameters
NC113/133/213/233/
• Sequence data
413/433
• Speed data
• Acceleration/deceleration time data
• Dual timer data
• Zone data
CJ1W-EIP21
• Unit settings
• Tag data link settings
8 Backup Operations
Data capacity used
in Memory Card
129 Kbytes
1.3 Kbytes
7 Kbytes
3.5 Kbytes
8,192 Kbytes
64 Kbytes
7 Kbytes
459 Kbytes
8-15
8