Sliu Initial Data Setup - NEC SL1100 Programming Manual

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

SL1100
Level:
IN
Description
Program
Use Program 82-11 : SLIU Initial Data Setup to define the various timers for SLIU.
82
Input Data
Item
No.
01
Bounce Protect Time
02
HookFlash Start Time
03
HookFlash End Time
Conditions
None
Feature Cross Reference
None
2-488
Program 82 : Basic Hardware Setup for
Item
Input Data
0 = No setting
1 ~ 15 = 100 ms ~ 1.5
sec
0 = 40 ms
1 ~ 15 = 90 ms ~ 790 ms
0 = HST + 0 ms
1 ~ 15 = HST + 100 ms
~ HST + 1500 ms
(HST = Hookflash Start
Time)

82-11 : SLIU Initial Data Setup

Description
Specify a time for detection of a valid off-
Hook indication that is long enough to pre-
vent an unintentional bounce of the receiv-
er from being detected as a new Off-Hook
indication from a Single Line Telephone.
Specify the minimum hookflash time from
a Single Line Telephone or analog Voice
Mail system before it is detected as the be-
ginning of a valid hookflash.
Specify the maximum hookflash duration
from a Single Line Telephone to receive a
second dial tone.
Program 82 : Basic Hardware Setup for Extension
ISSUE 4.0
Extension
Default
3
(300 ms)
5
(290 ms)
7
(990 ms)

Hide quick links: