Call Progress Tone Detector Frequency Setup - NEC SL1100 Programming Manual

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

ISSUE 4.0
Program 80 : Basic Hardware Setup for System

80-07 : Call Progress Tone Detector Frequency Setup

Level:
MF
Description
Use Program 80-07 : Call Progress Tone Detector Frequency Setup to set the frequency of the
detection tone set with Program 80-04-12 and Program 80-04-13.
Input Data
Frequency Table Number
Item
Item
No.
01
Frequency
Conditions
None
Feature Cross Reference
None
Programming Manual
Input Data
0, 10 ~ 255
(100 ~ 2550 Hz)
(0 = Not used)
SL1100
1 ~ 8
Default
Frequency Table No. 1
= 35 (350 Hz)
Frequency Table No. 2
= 44 (440 Hz)
Frequency Table No. 3
= 48 (480 Hz)
Frequency Table No. 4
= 62 (620 Hz)
Frequency Table No. 5
= 0
Frequency Table No. 6
= 0
Frequency Table No. 7
= 0
Frequency Table No. 8
= 0
2-459
Program
80

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents