Department Group Assignment For Extensions - NEC SL1100 Programming Manual

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

SL1100

16-02 : Department Group Assignment for Extensions

Level:
IN
Description
Use Program 16-02 : Department Group Assignment for Extensions to set the Department
Program
Groups. The system uses these groups (32 Department Groups) for Department Calling. Assign pilot
numbers to Department Groups you set up in Program 11-07. This lets system users place calls to the
16
departments. Use Program 16-01 to set the priority of each extension in each Department Group.
When a call comes to the group, the extensions ring in order of their priority.
Input Data
Item
No.
01
Group Num-
ber
Priority
The initial value of a priority becomes the ports numerical order assigned in Programs 11-02 and 11-04.
(Extension ports are 1 ~ 128 (V3.5 or higher) Virtual extension ports are 1 ~ 50.)
Conditions
None
Feature Cross Reference
• Department Calling
2-164
Program 16 : Department Group Setup
Extension Number
Item
Input Data
1 ~ 32
1 ~ 999
Default
Description
1 - xxx
Set up the Department Group called
by the pilot number and the exten-
(See
)
sion priority when a group is called.
Call Pickup Groups are set up in
23-02.
Program 16 : Department Group Setup
ISSUE 4.0
Maximum eight digits
Related Program
11-07
16-01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents