18
Installation (for qualified installers only)

Installation Without Surround Panels

The insert may be installed without surround panels.
control panel under the burner pan (see "Installation of the On/Off Switch and Rheostat" on page 19).

Surround Panel Installation

PANEL SIZE
8" x 10" Rectangular
Arched (8" x 10")
10" x 13" Rectangular
1
Follow the directions below to install the side panels.
b
Line up each side surround
panel and insert two screws from
the inside to secure in place.
2
Follow the directions below to install the top panel.
NOTE:
These 3/8"
stand-offs are
not required
and may be
flattened.
a
Install the top panel so the
two tabs insert into the slots
on the side panels.
© Travis Industries
WIDTH
HEIGHT
44-3/16"
33-3/8"
44-3/16"
33-3/8"
48-3/16"
36-3/8"
a
The insulation included with the
Top Trim
panels may be discarded.
Top
Panel
4080123
Mount the on/off switch and rheostat to the
PART #
98500606
98500608
98500607
Pre-thread the holes on the surround
panels with the screws included in the
surround panel kit.
5/16" Nutdriver
Run the rheostat wires,
on/off switch wires, and
power cord through the
access hole on the
insert
Construct the panel trim. Insert one leg of each "L"
b
bracket into the top and side trim piece. Align the
trim to form a precise corner, then tighten the two set
screws with a small standard screwdriver. Slide the
trim over the panels.
"L" Bracket
Slot for on/off
switch and hole
for rheostat
Top Trim
Right Side Trim
"L" Bracket
Right Side
Trim
Tighten the set
screws from the back
side with a small
standard screwdriver
100-01174_002