Outdoor Unit (Ras-24Ua-E4, Ras-24Uax4, Ras-24Uax3-T1); Outdoor Unit (Ras-24Ua-Ar4) - Toshiba RAS-24NKHD-E4 Service Manual

Split wall type
Table of Contents

Advertisement

4-5. Outdoor Unit (RAS-24UA-E4, RAS-24UAX4, RAS-24UAX3-T1
No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor

4-6. Outdoor Unit (RAS-24UA-AR4)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Magnetic contactor
5
Type
Output (Rated) 2200 W, 2 poles, 1 phase, 220 − 240 V, 50 Hz
PH400X3CS-4KT1 Winding resistance (Ω )
(at 20 °C)
Output (Rated) 65 W, 6 poles, 1 phase, 220 − 240 V, 50 Hz
Winding resistance (Ω )
KFG6-71SB5P-T
(at 20 °C)
AC 450 V, 3.5µF
451355L
AC 440 V, 45µF
BUM44X4505B
220 − 240 V, 50 Hz
A35
Type
Output (Rated) 2200 W, 2 poles, 1 phase, 220 − 240 V, 50 Hz
PH400X3CS-4KTS1 Winding resistance (Ω )
(at 20 °C)
Output (Rated) 65 W, 6 poles, 1 phase, 220 − 240 V, 50 Hz
Winding resistance (Ω )
MMF-230-65I
(at 20 °C)
AC 450 V, 3.5µF
451305L
AC 420 V, 60µF
SK42CMP60U1-S
220 − 240 V, 50 Hz
A35
− 18 −
FILE NO. SVM-05016
Specifications
C-R
1.13
Red-Black
64.4
Specifications
C-R
1.01
Red-Black
White-Black
71.2
C-S
2.10
White-Black
127.4
C-S
2.32
139.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents