Outdoor Unit (Ras-24Ua-Es3, Ras-24Ua-As3); Outdoor Unit (Ras-18Ua-Es3, Ras-18Ua-As3) - Toshiba AS-24UKHP-ES3 Service Manual

Table of Contents

Advertisement

4-5. Outdoor Unit (RAS-24UA-ES3, RAS-24UA-AS3)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor) KFG6-71SB5P-T Winding resistance (Ω)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Starting capacitor
(for compressor)
(RAS-24UA-AS3)
6
Magnetic contactor
7
Electric starter

4-6. Outdoor Unit (RAS-18UA-ES3, RAS-18UA-AS3)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor
Type
Output (Rated) 2200W, 2poles, 1 phase, 220 − 240V, 50Hz
5JS315DAB
Winding resistance (Ω )
(at 20°C)
Output (Rated) 65W, 6poles, 1 phase, 220 − 240V, 50Hz
(at 20° C)
451355KQ
AC 450V, 3.5µ F
371456JCR
AC 370V, 45µ F
371456JCR
AC 370V, 45µF
CLK-35J
220 − 240V, 50Hz
ZPR0YCE101A500 AC 500V, 100Ω
Type
Output (Rated) 1500W, 2poles, 1 phase, 220 − 240V, 50Hz
5KS225DAA
Winding resistance (Ω)
(at 20°C )
Output (Rated) 42W, 6poles, 1 phase, 220 − 240V, 50Hz
HF-240-42B-1
Winding resistance (Ω)
(at 20°C)
451205KQ
AC 450V, 2µF
371456JCR
AC 370V, 45µF
220 − 240V, 50Hz
CLK-26J
– 17 –
FILE NO. SVM-04007-(1)
Specifications
Red-Black
White-Black
0.83
Red-Black
White-Black
64.4
Specifications
Red-Black
White-Black
1. 632
Red-Black
176.2
2.257
127.4
2.457
White-Black
290.5

Advertisement

Table of Contents
loading