Outdoor Unit (Ras-24Ua-E-1, Ras-24Ua-Ar-1); Outdoor Unit (Ras-24Uax-1, Ras-24Uax-T-1) - Toshiba RAS-24UAH-E-1 Service Manual

Table of Contents

Advertisement

4-5. Outdoor Unit (RAS-24UA-E-1, RAS-24UA-AR-1)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor

4-6. Outdoor Unit (RAS-24UAX-1, RAS-24UAX-T-1)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Bimetal thermostat
6
Magnetic contactor
Type
Output (Rated) 2200 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
PH280X3-4MS
Winding resistance (Ω)
(at 20°C)
Output (Rated) 65 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
KFG6-71SB5P-T
Winding resistance (Ω)
(RAS-24UA-E-1)
(at 20°C)
Output (Rated) 65 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
MMF-230-65I
Winding resistance (Ω)
(RAS-24UA-AR-1)
(at 20°C)
451355KQ
AC 450 V, 3.5µF
371456JCR
AC 370 V, 45µF
(RAS-24UA-E-1)
SK-C2CMP45U1-S
AC 420 V, 45µF
(RAS-24UA-AR-1)
A35
220 – 240 V, 50 Hz
Type
Output (Rated) 2200 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
2JS386D5BB02
Winding resistance (Ω)
(at 20°C)
Output (Rated) 65 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
KFG6-71SB5P-T
Winding resistance (Ω)
(at 20°C)
451355KQ
AC 450 V, 3.5µF
SK42CMP60U1
AC 420 V, 60µF
CS-7C
Open 130 ± 5°C, Close 70 ± 10°C
A35
220 – 240 V, 50 Hz
– 20 –
FILE NO. SVM-03010(1)
Specifications
C-R
0.82
Red-Black
White-Black
64.4
Red-Black
White-Black
71.2
Specifications
C-R
0.886
Red-Black
White-Black
64.4
C-S
2.72
127.4
139.0
C-S
1.979
127.4

Hide quick links: