Indoor Unit; Ras-13Nkp-Hx, Ras-10Nkp-Hx); Outdoor Unit (Ras-13N2A-E, Ras-13N2Ax, Ras-12Nax-V) - Toshiba RAS-13NKHP-E2 Service Manual

Air conditioner split wall type
Table of Contents

Advertisement

4-3. Indoor Unit (RAS-13NKP-E2, RAS-13NKPX, RAS-12NKPX-V,

RAS-13NKP-HX, RAS-10NKP-HX)

No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
Transformer
4
Microcontroller unit (IC30)
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Bridge rectifier (DB50)
8
Capacitor (C50)
9
Fuse (F01)
10
Varistor (R21, R22)
11
Louver motor
12
Relay (Comp., RY01)

4-4. Outdoor Unit (RAS-13N2A-E, RAS-13N2AX, RAS-12NAX-V)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
Running capacitor
4
(for compressor)
Type
SKF- 220-20-4A-1
TT-10
TMP87CM40AN
*SS11V-06270
KBP06M/51
PF1E222MNN1625
BET6.3A
TND15G561K
MP24Z
DI1U
Type
Output (Rated) 1100 W, 2 poles, 1 phase, 220 - 240 V, 50Hz
PH225X2C-4FT
Winding resistance (W)
(at 20 C)
Output (Rated) 30 W, 6 poles, 1 phase, 220 - 240 V, 50Hz
HF-240-30B
or
Winding resistance (W)
WLF-240-30A
(at 20 C)
DS451155NPQB AC 450 V, 1.5µ
RS44B356U0125S AC 440 V, 35 F
- 15 -
Specifications
AC Motor with 150 C thermo fuse
W
°
10k at 25 C
°
W
10k at 25 C
27mH, 600mA
1.5A, 600 V
2200mF, 25 V
T6.3A, 250VAC
560 V
12VDC
Rating 25A/AC250 V, 3~48VDC
Specifications
°
°
m
FILE NO. SVM-06001
°
C-R
C-S
2.35
3.22
Red-Black
White-Black
245 or 237
388 or 380