Ras-18Nkdx4-T2 / Ras-18Uax4-T2 - Toshiba RAS-24NKHD-E4 Service Manual

Split wall type
Table of Contents

Advertisement

3-6. RAS-18NKDX4-T2 / RAS-18UAX4-T2

COLOR IDENTIFICATION
GRN&YEL : GREEN & YELLOW
BLK
P04
BLK
CN30
WHI
CN31
RED
GRN&YEL
CN27
POWER SUPPLY
220 V ~ 50 Hz
OUTDOOR
TERMINAL
L
BLOCK
BLK
BLK
Louver
BRW : BROWN
motor
RED : RED
WHI : WHITE
YEL
: YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
DRN : ORANGE
GRN : GREEN
Varistor
DSA
F01
6.3A 250V
MAIN P.C. BOARD
(WP-003)
Relay
INDOOR
TERMINAL
1
2
3
BLOCK
1
2
3
N
i
GRN&YEL
RED
CHASSIS
RED
BLK
BLK
GRY
SPARK KILLER
A1
52C
A2
RED
RED
R
U
CAPACITOR
S
V
T
W
MAGNETIC CONTACTOR
− 15 −
Infrared rays receive
and Indication parts
CN07
Power supply
circuit
Fan motor
Drive
circuit
CN11
CN10
Thermo
sensor
(TA)
AC Fan motor
INDOOR
UNIT
OUTDOOR
UNIT
i
RED
WHI
CAPACITOR
RED
FAN MOTOR
WHI
S
C
PNK
C
BLK
R
S
COMPRESSOR
COMPRESSOR TERMINAL
FILE NO. SVM-05016
CN25
CN34
CN13
BRW
BLU
BRW
BRW
BRW
+ 12 VDC
REW
CN33
+ 5 VDC
BLK
High-voltage
Power supply
WP-003
CN03
CN01
RED
BLK
Air purifier
electrode
Heat exchanger
sensor
(TC)
BLK
R
Micro SW
BRW
RED

Hide quick links: