Specifications - Toshiba RAS-24NKHD-E4 Service Manual

Split wall type
Table of Contents

Advertisement

ITEM
Capacity
Power source
Power consumption
Power factor
Running current
Indoor/Outdoor
Starting current
Moisture removal
Indoor (H/M/L)
Noise
Outdoor (220 – 240 V) dB
Name of refrigerant
Refrigerant
Rated amount
Refrigerant control
Gas side size
Connection type
Liquid side size
Interconnection
Connection type
pipe
Maximum length
(One way)
Maximum height
difference
INDOOR UNIT
Height
Dimensions
Width
Depth
Net weight
Evaporator type
Indoor fan type
High fan
Air volume
Medium fan
Low fan
Fan motor output
Air filter
OUTDOOR UNIT
Height
Dimensions
Width
Depth
Net weight
Condenser type
Outdoor fan type
Airflow volume
Fan motor output
Model
Compressor
Output
Safety device
Louver type
Usable outdoor temperature range
Note: * 1 Charge less pipe
* 2 Maximum pipe

1. SPECIFICATIONS

RAS-24NKD-E4
RAS-24NKHD-E4
MODEL
RAS-24UAH-E4
Cooling
Heating
220 V 240 V 220 V 240 V
220 V
kW
6.30 6.30 6.80 6.90
6.40
Phase
V
Hz
W 2430 2510 2390 2490
2350
%
96
92
94
90
220 V 240 V 220 V 240 V
220 V
A
0.3/ 0.3/ 0.3/ 0.3/
0.3/10.5
11.2 11.1 11.2 11.28
A
60
lit/h
2.5
dB
56-57
57-58
kg
1.75
mm
mm
m
m
RAS-24NKHD-E4
RAS-24NKD-E4
mm
mm
mm
kg
m
3
/h
m
3
/h
750
800
3
m
/h
600
650
W
RAS-24UAH-E4
RAS-24UA-E4
mm
mm
mm
kg
61
m
3
/h
3380
3380 3560 3380 3560
W
2JS386D5BB02
W
1800
IOL, Td Sensor
°C
15 ~ 43
–10 ~ 24
RAS-24NKDX4
RAS-24UAX4
RAS-24UA-E4
Cooling
Cooling
240 V
220 V
240 V
6.45
6.40
6.45
1∅
220 – 240
50
2440
2350
2440
99
90
99
90
240 V
220 V
240 V
0.3/11.0 0.3/10.50 0.3/11.0
67
67
45/43/41/39/37
56-57
R22
1.70
1.80
Capillary tube
∅15.88
Flare connection
∅6.35
Flare connection
15*
1
25*
2
10
RAS-24NKDX4
298
998
220
14
Finned tube
Cross flow fan
900
30
Honeycomb woven filter with PP frame
RAS-24UAX4
690
880
310
58
Finned tube
Propeller fan
3560
3380
3560
65
PH400X3CS-4KT1
1800
IOL
Automatic louver
15 ~ 43
21 ~ 43
– 3 –
FILE NO. SVM-05016
RAS-24NKD-AR4
RAS-24NKDX4-T
RAS-24UA-AR4
RAS-24UA X3-T1
Cooling
Cooling
220 V
240 V
220 V
6.40
6.45
6.40
220
2350
2440
2350
96
86
99
220 V
240 V
220 V
0.3/10.8
0.3/11.5
0.3/10.50
59
67
2.7
56
1.70
1.70
RAS-24NKD-AR4
RAS-24NKDX4-T
750
600
RAS-24UA-AR4
RAS-24UAX3-T1
59
58
3380
3560
3380
PH400X3CS-4KTS1
PH400X3CS-4KT1
1900
1800
21 ~ 52
21 ~ 43