7. MAINTENANCE AND TROUBLESHOOTING
LED
Status 4
If one of the Status LEDs 1- 4 is flashing, open the Web software on the PC to check
the message. (See section 7.6.)
7.4

Troubleshooting

If you think the equipment is not operating normally, do the checks in the table below
to find the possible causes. If repair of the equipment is necessary report the result of
the troubleshooting to the service technician. If you are asked the IMEI (International
Mobile Equipment Identify) number, do the following to find it.
• Handset: At the idle screen, press [*], [#], [0], [6], [#].
• Web software: On the menu bar, click [Main], [System information].
Condition
No power (POWER lamp
on communication unit
does not illuminate).
Nothing displays on hand-
set screen.
The handset keys do not
respond.
Does not become [Ready]
status.
7-4
Lamp Status
On
Handset is operating nor-
mally
Flashing (1 sec. in-
Problem with the handset
terval)
Flashing (0.2 sec.
Handset has significant
interval)
problem
Troubleshooting
• Check if the fuse has blown.
• Check if the power connector has loosened.
• Check if the power cable is rusted or damaged.
• Check if the power cable is damaged.
• Check if the voltage of the ship battery is within
range (10.8 - 31.2V DC).
• Check if the handset cable is properly connected to
the communication unit.
• Check the brightness level of screen is not too dark
Push and hold the
the handset. If keys continue to not respond after re-
start, contact your dealer.
• Check if the antenna cable is properly connected.
• Check that there are no objects blocking the signal
between antenna and satellite.
• In the Web software, do Main → satellite search to
do a manual satellite search.
• Check if the ship position data is correct ("No fix" or
"No data" appears, etc.).
• In the Web software, do Settings → Basic Settings
→ GPS to check if the backup GPS is set correctly.
Status
Normal state
Warning
Error
Check point
key for 3 seconds to restart
Note