MINIMUM ENCLOSURE CLEARANCES

Minimum clearance to combustible construction from fi replace
and vent surfaces:
Combustible framing:
-
0 " to stand-offs
Non-combustible fi replace fi nishing:
-
4 " from the sides of fi replace opening
-
22
3
/
" to the top of fi replace opening
8
Combustible fi replace fi nishing:
-
0 " to rear and sides
-
2" all around the vent pipe
1
-
22
/
" recessed depth
4
-
72 " from bottom of unit to enclosure top
-
72 " from bottom of unit to ceiling
FIGURE 32
Facing and/or fi nishing material must never overhang into the fi replace opening.
When using a rough fi nish material (i.e. stone), maintain a ¼" - ½" border from the framing
WARNING
!
Do not distort or force the frame kit components.
components.
HORIZONTAL VENT SECTIONS: A minimum clearance of 2" all around
the vent pipe on all horizontal runs to combustibles is required. Use
fi restop spacer W010-1799 (supplied).
VERTICAL VENT SECTIONS: A minimum of 1" all around the vent pipe
on all vertical runs to combustibles is required except for clearances in
fi replace enclosures. Use fi restop spacer W500-0096 (not supplied).