USING FLEXIBLE VENT COMPONENTS

FIGURE 19
ELBOW
Do not allow the inside vent pipe to
bunch up on horizontal or vertical runs
and elbows. Keep it pulled tight. A 1
1/4" air gap between the liner and the
SPACERS
outer liner all around is required for
safe operation. A spacer is required at
the start, middle and end of each
elbow to ensure this gap is maintained.
Spacers are attached to the inner
flexible vent pipe at predetermined
intervals to maintain a 1 1/4" air gap to
the outer flexible vent pipe. These
spacers must not be removed.

HORIZONTAL AIR TERMINAL INSTALLATION

Note: Direct vent
#10x2"
#10x2"
terminals shall
SCREWS
SCREWS
not be recessed
into a wall or
siding.
1. Stretch the
4" diameter
flexible vent pipe
to the required
length taking into
account the
additional length
needed for the finished wall surface. Slip the liner a minimum of
2" over the inner sleeve of the air terminal and secure with 3 #8
screws. Apply a heavy bead of the high temperature sealant
W573-0007 (not supplied).
2. Using the 7" diameter flexible vent pipe, slide over the outer
combustion air sleeve of the air terminal and secure with 3 #8
screws. Seal as before.
3. Insert the vent pipe through the firestop maintaining the
required clearance to combustibles. Secure to the exterior wall
and make weather tight by sealing with caulking W573-0002 (not
supplied).
4. If more vent pipe needs to be used to reach the fireplace,
couple them together as illustrated in (Fig. 20). The vent system
must be supported
HIGH TEMP
HIGH TEMP
SEALANT
SEALANT
approximately every 3
feet for both vertical
and horizontal runs.
Use non-combusible
strapping to maintain
7" FLEX
7" FLEX
the minimum 1"
PIPE
PIPE
clearance to combus-
tibles.
WARNING
!
FIGURE 20
CAULKING
CAULKING
5"FLEX
5"FLEX
PIPE
PIPE
8" FLEX
PIPE
8" FLEX
PIPE
2" OVERLAP
2" OVERLAP
HI-TEMP
HI-TEMP
SEALANT
SEALANT
#8 X 1/2" SELF DRILLING
#8 X 1/2" SELF DRILLING
SCREWS & WASHERS
SCREWS & WASHERS
4" COUPLER 7" COUPLER
4" COUPLER 7" COUPLER
7" FLEX PIPE
7" FLEX PIPE
4" FLEX
4" FLEX
PIPE
PIPE
FIGURE 21
For safe and proper operation of the fireplace, follow the venting
instructions exactly.
All inner exhaust and outer intake vent pipe joists may be sealed
using either red RTV high temp silicone sealant or black high
temp Mill Pac with the exception of the fireplace exhaust flue
collar which must be sealed using Mill Pac (not supplied).
Use only approved flexible vent pipe kits marked:
"Wolf Steel Approved Venting" as identified
by the stamp only on the 7" outer vent pipe.
Six inches (6") is the minimum bend radius allowed for the seven
inch (7") diameter flexible vent pipe.
For optimum performance it is recommended that all horizontal
runs have a minimum 1" rise per foot using flexible venting.

VERTICAL AIR TERMINAL INSTALLATION

1. Move the fireplace into position.
2. Fasten the roof
support to the roof
using the screws
provided. The roof
support is optional. In
this case the venting is
to be adequately
supported using either
an alternate method
suitable to the authority
having jurisdiction or
the optional roof
support.
3. Stretch the inner flexible vent pipe to the required length.
Slip the liner a minimum of 2" over the inner vent pipe of the air
terminal connector and secure with 3 #8 screws. Seal using a
heavy bead of the high temperature sealant W573-0007 (not
supplied).
4. Repeat using the outer
flexible vent pipe.
5. Thread the air terminal
connector / pipe assembly
down through the roof. The air
terminal must be located
vertically and plumb. Attach
the air terminal connector to the
roof support, ensuring that the
top of the air terminal is 16"
above the highest point that it
penetrates the roof. If the attic
space is tight, we recom-
mend threading the Wolf
Steel vent pipe collar or
equivalent loosely onto the
air terminal assembly as it is
passed through the attic.
6. Remove nails from the
shingles, above and to the
sides of the chimney. Place the flashing over the air terminal
connector leaving a min. 3/4" of the air terminal connector
showing above the top of the flashing. Slide the flashing
underneath the sides and upper edge of the shingles. Ensure that
the air terminal connector is properly centred within the flashing,
giving a 3/4" margin all around. Fasten to the roof. Do not nail
through the lower portion of the flashing. Make weather-tight by
sealing with caulking. Where possible, cover the sides and top
edges of the flashing with roofing material.
13
FIGURE 22a
ROOF SUPPORT
INNER
PIPE
AIR
FIGURE 22b
TERMINAL
CONNEC-
TOR
HIGH
TEMPERATURE
SEALANT
INNER FLEXIBLE
VENT PIPE
OUTER FLEXIBLE
VENT PIPE
DO NOT CLAMP THE
FLEXIBLE VENT PIPE
W415-0666 / 01.28.08