DCR-TRV940/TRV940E/TRV950/TRV950E

17. Mechanical Shutter Adjustment

Adjust the close time and loss time every F number of the me-
chanical shutter and the high-speed shutter correction value to
correct the luminous exposure.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note 1: Perform "HALL Adjustment", "Flange Back Adjust-
ment" and "F No. & ND Light Quality Standard Data
Input" before this adjustment.
Note 2: With the ZOOM at WIDE end, set the distance where
the clear chart is shot with all-white signal.
Note 3: Check that the data of page: 0, address: 10 is "00".
Note 4: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Switch setting
1) POWER ................................................................... CAMERA
2) ZOOM .................................................................... WIDE end
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
1
0
01
2
6
30
3
6
9C
4
6
01
5
6
02
6
6
A8
Note 5: The adjustment data will be automatically input to page:
F, address: 90 to A5.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
30
3
6
9C
4
0
01
RadarW
RadarW
RadarW
RadarW
RadarW
Clear chart (All white)
(Zoom lens at WIDE end) (Note 2)
Adjusting remote commander
F
90 to A5
Data of page: 6, address: A8 is "00"
Procedure
01
01
01
AD Press PAUSE button. (Note 5)
Check the data changes to "01".
Check the data is "00".
Procedure
00
Press PAUSE button.
00
00
00

18. Strobe Light Level Adjustment

Adjust the strobe light level.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note 1: Perform "Hall Adjustment", "Flange Back Adjustment"
and"F No. & ND Light Quality Standard Data Input"
before this adjustment.
Note 2: Restrict external light to enter the Flash adjustment box
as less as possible.
Note 3: Refer to "4. Preparing the Flash adjustment box".
Note 4: Check that the data of page: 0, address: 10 is "00".
Note 5: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Switch setting
1) POWER ................................................................... CAMERA
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting) ..................................... OFF
4) Flash .............................................................................. OPEN
(Press the FLASH button to activate the Flash mode, and then
press the PHOTO button.)
Adjusting method:
Order Page Address Data
1
0
01
2
7
05
3
6
30
4
6
01
5
6
6
02
7
6
B8
Note 6: Press the STOP button on the adjusting remote com-
mander, and set the data.
Note 7: The adjustment data will be automatically input to page:
F, address: 8A to 8F.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
30
3
7
05
4
0
01
6-38
RadarW
RadarW
RadarW
Flash adjustment box (Note 3)
(50 cm from the front of the lens)
Adjusting remote commander
F
8A to 8F
Data of page: F, address: B8 is "00"
Procedure
01
04
(Note 6)
02
Press PAUSE button.
67
(Note 7)
Check the flashing of strobe
light
Check the data changes to
"01".
Check the data is "00".
Procedure
00
Press PAUSE button.
00
00
00