DCR-TRV940/TRV940E/TRV950/TRV950E
20. Hologram AF Output Adjustment
Adjust so that the laser output of the hologram AF becomes proper
value.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value 1
Specified Value 2
Specified Value 3
Specified Value 4
Note 1: Perform "Hall Adjustment", "Flange Back Adjustment",
"F No. & ND Light Quality Standard Data Input" and
"AWB Standard Data Input" before this adjustment.
Note 2: Restrict external light to enter the Flash adjustment box
as less as possible.
Note 3: Refer to "4. Preparing the Flash adjustment box".
Note 4: Make adjustment with the lens hood removed.
Note 5: Check that the data of page: 0, address: 10 is "00".
Note 6: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Switch setting
1) POWER ................................................................... CAMERA
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
1
0
01
2
6
30
3
6
01
4
6
02
5
F
7D
6
F
82
7
F
7E
8
F
7F
Note 7: The adjustment data will be automatically input to page:
F, address: 7D to 83.
At this time, check that the laser holograms are all dis-
played on the monitor TV screen.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
30
3
0
01
RadarW
RadarW
RadarW
RadarW
RadarW
Flash adjustment box (Note 3)
(50 cm from the front of the lens)
Adjusting remote commander
F
7D to 83
10 to FF
34 to 4C
00 to F0
0A to FF
Procedure
01
02
Press PAUSE button.
AF
(Note 7)
Check the data changes to
"01".
Check that the data satisfied
the specified value 1.
Check that the data satisfied
the specified value 2.
Check that the data satisfied
the specified value 3.
Check that the data satisfied
the specified value 4.
Procedure
00
Press PAUSE button.
00
00
6-40