Mechanical Shutter Adjustment; Steady Shot Check - Sony DCR-PC350 Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-PC350:
Table of Contents

Advertisement

21. Mechanical Shutter Adjustment

Adjust the period which the mechanical shutter is closed for every
F number, and compensate the exposure.
Adjustment Page
Adjustment Address
Note1: The data of page: 0, address: 10 must be "00".
Note2: NTSC model: DCR-PC350
PAL model: DCR-PC350E
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Input the following data to page: F, addresses: 76 to 8B.
Note: Press the PAUSE button each time to set the data.
Address
NTSC
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
3)
Select page: 0, address: 01, and set data: 00.
DCR-PC350/PC350E
F
76 to 8B
Data
PAL
C5
A4
00
00
86
6F
00
00
67
55
00
00
51
43
00
00
3F
35
00
00
50
4E
5D
5B
5A
57
4F
4B
3E
3A
20
20
7C
7E
81
81
80
80
80
80
80
80
7D
7D

22. Steady Shot Check

Precautions on the Parts Replacement
There are two types of repair parts.
Type A: ENC03MA
Type B: ENC03MB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Measurement Point
Measuring Instrument
Specified Value
Note1: Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Note2: The data of page: 0, address: 10 must be "00".
Switch setting:
1) STEADY SHOT (CAMERA SET menu) ......................... ON
2) ZOOM .................................................................... TELE end
Adjusting method:
Order Page Address Data
1
0
03
2
1
3
0
03
4
1
Processing after Completing Adjustments:
Order Page Address Data
1
0
03
2
6-37
Arbitrary
Display data of page 1 (Note1)
Adjustment remote commander
2680 to 5080
Procedure
Pitch sensor check
(SE-151 board SE2501)
11
Set the data.
Check that the display data (Note1)
satisfies the specified value.
Yaw sensor check
(SE-151 board SE2500)
12
Set the data.
Check that the display data (Note1)
satisfies the specified value.
Procedure
00
Set the data.
Move the camcorder, and check
that the steady shot operations
have been performed normally

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Dcr-pc350e

Table of Contents