16. Mechanical Shutter Adjustment

Adjustment Page
F
Adjustment Address
76 to 8B
Note1: The data of page: 0, address: 10 must be "00".
Note2: NTSC model: DCR-IP210/IP220
PAL model: DCR- IP210E/IP220E
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Input the following data to page: F, addresses: 76 to 8B.
Note: Press the PAUSE button of the adjustment remote commander each
time to set the data.
Address
NTSC
76
92
77
7F
78
65
79
7C
7A
50
7B
7E
7C
41
7D
7F
7E
35
7F
80
80
5D
81
64
82
66
83
62
84
5A
85
22
86
6D
87
83
88
80
89
80
8A
80
8B
6E
3)
Select page: 0, address: 01, and set data: 00.
Data
PAL
6F
8A
4B
77
3B
91
2F
7D
26
81
50
63
65
60
5A
24
7A
80
80
80
80
79
DCR-IP210/IP210E/IP220/IP220E

17. Strobe Light Level Adjustment

Adjust the light level when the strobe light flashes.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: Background paper (J-250-130-A). Perform this adjustment in the
dark room or use the flash adjustment box. (Refer to "1-1-
3.Precaution".)
Note2: Any light other than the strobe light should not light up the paper.
Note3: This adjustment should be carried out upon completion of "HALL
Adjustment", "Flange Back Adjustment".
Note4: The data of page: 0, address: 10 must be "00".
Note5: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
FLASH ......................................................................... OPEN
(Press FLASH ( ) button and set to the forced flash mode ( ),
and press PHOTO button.)
3)
NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data
1
0
01
2
7
05
3
6
01
4
5
6
02
6
6
B8
Note6: Use the STOP button of the adjustment remote commander.
Note7: The adjustment data will be automatically input to page: F, address:
8C to 91.
Processing after Completing Adjustments:
Order Page Address Data
1
6
01
2
7
05
3
0
01
6-33
Paper which reflection rate is 18%
(50cm from the front of the lens)(Note1)
Adjustment remote commander
F
8C to 91
Data of page: 6, address: B8 is "00".
Procedure
01
Set the data.
04
Set the data. (Note6)
67
Set the data, and press PAUSE
button.
Check the flashing.
Check that the data is "01".
(Note7)
Check that the data is "00".
Procedure
00
Set the data, and press PAUSE
button.
00
Set the data.
00
Set the data.

Advertisement