Angular Velocity Sensor Sensitivity Adjustment - Sony DCR-TRV940 Adjustment Manual

Hide thumbs Also See for DCR-TRV940:
Table of Contents

Advertisement

16. Angular Velocity Sensor Sensitivity Adjustment

• Perform the angular velocity sensor sensitivity adjustment only
when replacing the angular velocity sensor or lens block. When
the microprocessor, circuit, etc. malfunctions, do not perform
this adjustment but check operations only.
• Record the sensitivity label of the angular velocity sensor (re-
pair part), including to which side of the board it was attached
to, etc. If it has been attached incorrectly, the image will move
up and down or to the left and right during steady shot opera-
tion. Be sure to take note of this.
Precautions on the Parts Replacement
There are two types of repair parts.
Type A
ENC03MA
Type B
ENC03MB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations. After replacing,
readjust according to the adjusting method after replacement.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Adjustment Page
F
Adjustment Address
86, 87
Note 1: Check that the data of page: 0, address: 10 is "00".
Note 2: The sensor sensitivity (SE4001, SE4002 of SE-132 board)
is labeled only on the repair parts.
Switch setting
1) POWER ................................................................... CAMERA
2) ZOOM ..................................................................... TELE end
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ....................................... ON
Adjusting method:
Order Page Address Data
1
0
01
01
2
3
4
5
6
F
86
D
7
F
87
D
Note 3: The value that is calculated at "15. PSD Sensor Gain
Adjustment" is used for D
Note 4: Refer to table 6-4-1. "Hexadecimal-decimal conversion
table"
Procedure
Read the sensor sensitivity of
SE4001, and it is named
S
.
4001
Read the sensor sensitivity of
SE4002, and it is named
S
.
4002
Calculate D
', D
' using
86
87
following equations.
(decimal calculation) (Note 3)
× (0.60 ÷ S
) × 88
D
' = D
86
SV
4001
× (0.60 ÷ S
) × 88
D
' = D
87
SH
4002
Convert D
', D
' to a
86
87
hexadecimal number, and
obtain D
, D
. (Note 4)
86
87
Press PAUSE button.
86
Press PAUSE button.
87
and D
.
SV
SH
DCR-TRV940/TRV940E/TRV950/TRV950E
Processing after Completing Adjustment:
Order Page Address Data
1
0
01
2
6-37
Procedure
00
Check that the steady shot
function operates normally.