Electronic Ignition System - (continued)
Symptom
a. Flame impingement on logs.
b. Improper venturi setting.
10. Glass soots.
c. Debris around venturi.
11. Flame burns blue
a. Insuffi cient oxygen being
and lifts off burner.
supplied.
33
Possible Causes
Adjust the log set so that the fl ame does not impinge on it.
Adjust the air shutter at the base of the burner.
Inspect the opening at the base of the burner. It is imperative that NO material be
placed in this opening.
1. Check to make sure fl ue cap is installed properly and free of debris. Make sure
that fl ue system points are tight and have no leaks.
2. Check to make sure that no material has been placed in the opening at the
burner base or in the area of the air holes in the center of the base pan be-
neath the burner.
3. Be sure glass is tightened properly on unit, particularly on top corners.
Heat & Glo • 6000TRSI-AUC • 2078-900 Rev. Q • 6/10
Corrective Actions