STRAIGHT OUT HORIZONTAL FLUE SYSTEM
Figure 1.8 shows straight out horizontal fl ue systems
approved for use on this model.
H
MIN. RUN
13.1" (331 mm)
H
Figure 1.8 Straight Out Horizontal Flueing
ELBOWS
The fl ue systems installed on this gas heater may also
include one (1), two (2), or three (3) 90 - degree elbow
assemblies.
Figures 1.9 through 1.15 and their corresponding
tables show examples of fl ue confi gurations using
elbows. The relationships of vertical rise to horizontal
run in fl ue confi gurations using elbows MUST be strictly
adhered to.
10
H
MAX. RUN
24" (610 mm)
Heat & Glo • 6000TRSI-AUC • 2078-900 Rev. Q • 6/10
V
1´ MIN. (0.30 M)
2´ MIN. (0.61 M)
3´ MIN. (0.91 M)
4´ MIN. (1.22 M)
24´ MAX. (7.32 M)
V
Figure 1.9 Flueing with One 90° Elbow
ONE (1) 90-DEGREE ELBOW
Figures 1.9 and 1.10 show an installation using one (1)
90-degree elbow. Dimension V is listed as MINIMUM
vertical dimensions and dimension H is listed as cor-
responding MAXIMUM horizontal dimensions.
TWO (2) 90-DEGREE ELBOWS
Figures 1.11 and 1.12 show examples of possible in-
stallations using two (2) 90-degree elbows. Dimension
V is listed as MINIMUM vertical dimensions, dimension
H is listed as MAXIMUM beginning horizontal dimen-
sions, and dimension H + H
TOTAL MAXIMUM horizontal dimensions.
THREE (3) 90-DEGREE ELBOWS
Figures 1.13 through 1.15 show examples of possible
installations using three (3) 90-degree elbows. Dimen-
sions V are listed MINIMUM fi rst vertical dimensions
and dimensions H are listed as beginning MAXIMUM
horizontal dimensions. Dimensions H + H
H
+ H
are listed as TOTAL MAXIMUM horizontal
1
2
dimensions. Dimensions V + V
MAXIMUM vertical dimensions.
H
2´ MAX. (0.61 M)
4´ MAX. (1.22 M)
6´ MAX. (1.83 M)
8´ MAX. (2.44 M)
8´ MAX. (2.44 M)
H
is listed as corresponding
1
and H +
1
are listed as TOTAL
1