E. Maintenance Tasks
Inspect
Doors
1. Inspect for scratches, dents or other damage and repair as necessary.
2. Verify no obstructions to airfl ow.
3. Verify maintenance of proper clearance to combustible household objects.
Gasket Seal, Glass
1. Inspect gasket seal and its condition.
Assembly and Glass
2. Inspect glass panels for scratches and nicks that can lead to breakage when exposed to heat.
3. Confi rm there is no damage to glass or glass frame. Replace as necessary.
4. Verify that latches engage properly, clip studs are not stripped, and glass attachment components
5. Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot be re-
Valve Compartment
1. Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas.
and Firebox Top
2. Remove any foreign objects.
3. Verify unobstructed air circulation.
Logs
1. Inspect for broken, damaged, or missing logs. Replace as necessary.
2. Verify correct log placement and no fl ame impingement causing sooting. Correct as necessary.
Firebox
1. Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as necessary.
2. Replace appliance if fi rebox has been perforated.
Burner Ignition and
1. Verify burner is properly secured and aligned with pilot or igniter.
Operation
2. Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if neces-
3. Replace ember materials with new dime-size and shape pieces. Do not block ports or obstruct light-
4. Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.
5. Inspect for lifting or other fl ame problems.
6. Inspect orifi ce for soot, dirt or corrosion.
7. Verify manifold and inlet pressures. Adjust regulator as required.
8. Inspect pilot fl ame strength. Clean or replace orifi ce as necessary.
9. Inspect thermocouple/thermopile or IPI sensor rod for soot, corrosion and deterioration. Clean with
Flueing
1. Inspect venting for blockage or obstruction such as bird nests, leaves, etc.
2. Confi rm that termination cap remains clear and unobstructed by plants, etc.
3. Verify that termination cap clearance to subsequent construction (building additions, decks, fences
4. Inspect for corrosion or separation.
5. Verify weather stripping, sealing and fl ashing remains intact.
Remote controls
1. Verify operation of remote.
2. Replace batteries in remote transmitters and battery-powered receivers.
31
are intact and operating properly. Replace as necessary.
moved.
Screw tips that have penetrated the sheet metal are sharp and should be avoided.
sary.
ing paths.
emery cloth or replace as required.
or sheds) has been maintained.
Heat & Glo • 6000TRSI-AUC • 2078-900 Rev. Q • 6/10